Construction parts containing fl ammable substances or material and fi tted
furniture outside the radiation area of the fi tted fi replace
There must be a distance of at least 5 cm between the outside surfaces of the chimney
breast/casing/fi replace into which the fi re is built and the construction parts of infl ammable
building material and infl ammable components, such as integrated furniture.
Expansion seams
Between the fi re and its casing/fi replace, an expansion seam must be factored in to
calculations. This may be fi lled in with ceramic sealing tape.