17
ENGLISH
ATLANTA
SAVANNAH
ECO 550
ECO 650
ECO 750
3
MAINTENANCE
3.1
ANNUAL MAINTENANCE
The appliance must be checked and cleaned annually by an authorised engineer.
This also applies to the chimney.
The annual maintenance consists of the following points:
l
Cleaning the main burner, pilot light and chimney liner(s)l/combustion air
supply.
l
Removing dust deposits using a vacuum cleaner.
l
Checking the gas, flue and combustion air supply route for leaks.
l
Checking the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
l
Checking the operation of the security system.
4.
FAULTS
Possible reasons for the gas fire going out are:
•
Operation of the security system due to flue gas escape.
•
Malfunction of the security system. Check by means of testing.
l
Insufficient gas pressure.
l
The pilot light is either dirty or defective.
l
Thermocouple voltage is too low. This is usually caused by insufficient heating
at the tip of the thermocouple by the pilot light.
l
Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection, T.T.B. wiring and/or connections of the security
system.
Summary of Contents for ATLANTA
Page 3: ...4 ECO 550 ECO 650 ECO 750 SAVANNAH A TLANTA...
Page 18: ...19 ENGLISH A TLANTA SAVANNAH ECO 550 ECO 650 ECO 750 Figure 7 ATLANTA SAVANNAH ECO 550...
Page 21: ...22 ECO 550 ECO 650 ECO 750 SAVANNAH A TLANTA Gas connection 6 2 ECO 550...
Page 22: ...23 ENGLISH A TLANTA SAVANNAH ECO 550 ECO 650 ECO 750 Gas connection 6 3 ECO 650...
Page 23: ...24 ECO 550 ECO 650 ECO 750 SAVANNAH A TLANTA Gas connection 6 4 ECO 750...