ToughRunners / ScanWear – Communication Protocol v1.1
- 10 -
Data Capture
for Workforce
in Motion
3.4.
3.4.
3.4.
3.4.
Restore default settings
Restore default settings
Restore default settings
Restore default settings
Command ID
0x0F
Description
Restore factory default settings (reboots scanner)
Length
1
payload
A = 0
Response
none
3.5.
3.5.
3.5.
3.5.
MMI settings
MMI settings
MMI settings
MMI settings
Command ID
0x40
Description
Get vibrator
Length
0
payload
none
Response
ABC
where :
A = Vibration duration on BAD READ event
B = Vibration duration on BARCODE LOST event
C = Vibration duration on NACK event
Durations in 1/10 sec
Default settings:
0x0A 0x0A 0x0A
Command ID
0x41
Description
Set vibrator
Length
3
payload
ABC
where :
A = Vibration duration on BAD READ event