ToughRunners / ScanWear – Communication Protocol v1.1
- 24 -
Data Capture
for Workforce
in Motion
BB = radio shutdown timer when in Master mode (sec.)
CC = radio shutdown timer when in Slave mode (sec.)
U = 0 (unused)
Default settings :
0x04 0xB0 0x04 0xB0 0x04 0xB0 0x00
Command ID
0xF1
Description
Set shutdown timers
Length
7
payload
AABBCCU
Where:
AA = scanner shutdown timer (sec.)
BB = radio shutdown timer when in Master mode (sec.)
CC = radio shutdown timer when in Slave mode (sec.)
U = 0 (unused)
Response
0 (1 = ERROR)
Command ID
0xF2
Description
Get battery status
Length
0
payload
None
Response
1 byte:
Bits A.0-6 = battery level (RFU)
Bit A.7 = 1
low battery