PKT-GD/GS-IM-DE-B-EN-09-19 Rev.0
27
Make sure that the optical position indicator
together with a ball valve or flap always cor-
responds to the ball bore/disc.
Make sure that the maximum torques of the
flange pattern used are not exceeded for
the sake of design and operation!
Connecting surfaces must be free from oil
and grease, clean and dry.
1.
Place the rotary actuator on the valve
spindle (7). If necessary, install prior re-
quired components such as, for exam-
ple, shaft adapter, reduction, mounting
bridges and/or centering.
2.
Slightly grease the connecting bolts.
3.
Tighten the connecting screws on the
flange pattern (9) according to
Tab. 5-3.
Fig. 5-2
7
9
View on rotary actuator from bottom =
valve interface
7
Installation of the valve spindle / shaft
adapter
9
Installation of the connecting screws
Observe the following tightening torques
when installing connecting bolts:
Flange
pattern
Screw size
Tightening
torque
[Nm]
F03
M5
6
F04
M5
10
F05
M6
10
F07
M8
25
F10
M10
49
F12
M12
85
F14
M16
145
F16
M20
310
F25
M16
145
Tab. 5-3 Tightening torques for connecting
screws of rotary actuator – valve
5.4.1 Installation of the pneumatic
connection
Fig. 5-3
4
2
10
10
Pneumatic connections of the rotary
actuator bar-agturn
2
Pneumatic connection
4
Pneumatic connection
10
Threaded hole M5
Make sure that plugs or end caps are re-
moved at the pneumatic connections 2 and
4, if necessary.
Summary of Contents for agturn PKT Series
Page 1: ...3 2 way automatic valve of PKT type Translation of the original operating manual bar gmbh de...
Page 38: ...38 PKT GD GS IM DE B EN 09 19 Rev 0 12 EU Declaration of Incorporation...
Page 43: ...PKT GD GS IM DE B EN 09 19 Rev 0 43...
Page 49: ...49 Notes...
Page 50: ...50 Notes...