22
PKT-GD/GS-IM-DE-B-EN-09-19 Rev.0
3.3.3 Operating and display
elements
The positions of the valve are indicated by
an optical position indicator mounted on the
rotary actuator. The yellow and black clips
can be remounted according to the instal-
lation situation.
Fig. 3-10
1
Operating and display elements of the
rotary actuator bar-agturn
Longitudinal design = closed position
Transverse design = open position
Fig. 3-11
1
Operating and display elements of the
rotary actuator bar-agturn
Longitudinal design = open position
Transverse design = closed position
In case of
longitudinal design
the position
indicator shall be mounted as follows:
•
Fig. 3-10 indicates the closed position
•
Fig. 3-11 indicates the open position
Optionally the rotary actuator bar-agturn
can be mounted
transversely to the pipe-
line
. The position indicators are mounted as
follows:
•
Fig. 3-10 indicates the open position
•
Fig. 3-11 indicates the closed position
NOTE
Make sure that the optical position indica-
tor together with a ball valve always cor-
responds to the ball bore or, in the case of
a butterfly valve, always corresponds to
the disc.
3.3.4 Accessories
DANGER
Danger of explosion
An explosion can occur if components are
operated with insufficient protection class
and without approved explosion protec-
tion.
•
When selecting the pneumatic valves
and the accessories, pay attention to
the combination with Ex-approved
products.
Contact your bar customer service for se-
lection of the right accessories:
•
Throttle plates
•
Silencer
•
End position feedback devices
•
Solenoid valves
•
Positioner
Summary of Contents for agturn PKT Series