Mount the System Components

Mounting hardware is not included with the Occupancy Solution Kit. Banner recommends using ¼-20 mounting bolts, self 
tapping screws, magnetic mounts, or hardware that is compatible with the mounting surface.
Do not mount any radios inside metal enclosures. Metal around the radios can reduce wireless signal strength.

Mount the Indicator Light indoors when 
possible and mount so that people entering 
the monitored area are able to see the 
occupancy status.
Mount the indicator light using the supplied 
bracket and ¼-20 mounting bolts, self 
tapping screws, or optional magnetic 
mounts listed at the end of this document.

Mount the DXM Controller in a secure 
location, outside of any metal cabinets or 
enclosures.
The DXM Controller has four mounting 
holes. Use ¼-20 mounting bolts or self 
tapping screws to secure the controller to 
a rigid surface.

The Operator Interface can be mounted near each monitored door, in a central supervisory 
location, or can be held by an employee to actively monitor the occupancy level.
Mount the Operator Interface to a rigid surface using the mounting holes and  ¼-20 bolts, 
self tapping screws, or optional magnetic mounts listed at the end of this document.

How you mount your sensor varies based on the application requirements. User-provided custom mounting fixtures may be 
required in cases where the supplied brackets are not compatible with the installation location. Contact your local distributor or 
Banner Engineering’s Technical Support team at 1-800-203-5616 for more options or refer to our Troubleshooting section on page 
9.

When mounting the Directional Sensor Pair, Banner recommends the sensors be 
mounted indoors when possible. The arrows on the face of the Emitter-Receiver Sensor 
Pair must point towards the inside of the building/monitored area. Mount the sensors 
using two 1/4”-20 mounting bolts, self tapping screws, or the optional magnetic brackets. 
Use the side arrows on the Emitter and Receiver to mount the sensor in the correct 
orientation.
When mounting the Directional Sensor Pair using the supplied brackets:

1.  Mount the Emitter bracket to a rigid surface. 
2.  Mount the Receiver bracket at the same height as the Emitter bracket. Follow the 

bracket assembly instructions on page 4 to re-assemble the Sensors to the bracket.

3.  Align the Receiver by rotating the housing until it is perpendicular to the Emitter. Two 

yellow alignment LEDs should begin to flash on the Receiver when it is aligned. 

When mounting the Directional Sensor Pair using the sensor housing mounting holes:

1.  Mount the Emitter against a flat surface using the two mounting holes.
2.  Place the Receiver across from the Emitter and position it at the same height as the Emitter. Move 

the Receiver horizontally until the two yellow Alignment LEDs begin to flash.

3.  Secure the Receiver after it has been aligned to the Emitter.

2. Connect the power supply to the 
Indicator Light, aligning the keys in the 
connector. Hand tighten.
3. Connect the power supply into a 
power outlet using the appropriate 
regional wall adapter.

Supply Power to the TL70 Wireless Indicator Light and Mount to the Bracket

1. Position the Indicator Light on the 
bracket so that the icons are facing 
the desired orientation. 
Secure with the supplied lock nut. 
Hand tighten only.

Mounting Recommendations

•  Mount the Directional Sensor Pair so that the sensor’s top is at a minimum height of 1.25 m (50 in) to avoid the potential for miscounts. 

Mounting the sensor at a height below 1.25 m (50 in) may result in double counts by detecting arm or leg motion. The Directional 
Sensor Pair may need to be mounted higher than 1.25 m (50 in) to avoid counting arm motion or people carrying or pushing objects. 

•  Mount the Emitter and Receiver less than 30 ft from each other for optimal performance.

Yellow alignment LED

Summary of Contents for TCER

Page 1: ...219271 Rev A Occupancy Solution Kit Total Count Emitter Receiver TCER Setup Guide ...

Page 2: ...icator includes bracket and power supply Receiver includes D cell battery and ISM radio DXM Controller Not shown above Direct Select Operator Interface includes C battery Power Supply Tools Needed Tape measure Phillips screwdriver Hand drill Emitter includes D cell battery ...

Page 3: ...enclosures The Emitter Receiver Directional Sensor Pair detects whether a person is entering or exiting the monitored area The sensor pair comes with two components an emitter and a receiver with an internal radio The receiver has a radio icon on the cover and base of the sensor Mount the sensor pair according to Banner s suggested mounting instructions The Direct Select Operator Interface display...

Page 4: ... corner screws with a Phillips screwdriver and open the Operator Interface 2 Insert the 3 6 V lithium battery Verify the battery s positive and negative terminals align to the positive and negative terminals as marked Caution There is risk of damage if the batteries are installed incorrectly Status LED 1 Unscrew the four corner screws with a Phillips screwdriver on the Receiver and remove the cove...

Page 5: ...ored area Mount the sensors using two 1 4 20 mounting bolts self tapping screws or the optional magnetic brackets Use the side arrows on the Emitter and Receiver to mount the sensor in the correct orientation When mounting the Directional Sensor Pair using the supplied brackets 1 Mount the Emitter bracket to a rigid surface 2 Mount the Receiver bracket at the same height as the Emitter bracket Fol...

Page 6: ... where people will stand and block the sensors Inward Opening Doors For occupancy monitoring in areas with inward opening doors Banner recommends mounting the devices on the inside of the door and far enough from the door that the door does not block the sensor pair when opening The supplied bracket allows for sensor rotation for an angled mounting The sensors should be mounted to the supplied bra...

Page 7: ...Registers menu and press ENTER Highlight Occupancy Limit and press ENTER Enter your desired Occupancy Limit 1 Using the up and down arrow buttons select the first digit for the limit and press ENTER to set the first digit 2 Use the up and down arrows to set the second digit and press ENTER 3 Repeat if you are adding a third digit 4 Press ENTER once more to highlight SEND and press ENTER to confirm...

Page 8: ...e reset schedule Operator Interface no longer displays the counts After the DXM Controller is rebooted a delay of 5 minutes may occur before counts are displayed The Operator Interface may not be communicating with the DXM Controller Check the status LED above the check mark button If the status LED flashes red change the positioning of the DXM Controller or Operator Interface so that they are clo...

Page 9: ...s if directed to by your IT department Setting a Static IP Address To define a specific IP address of your choosing 1 On the DXM use the arrows and move to the System Config menu Press ENTER 2 Use the arrow keys to select the Ethernet menu Press ENTER 3 Highlight the DHCP selection and press ENTER Set DHCP to OFF 4 The system will request a restart press ENTER to confirm 5 Follow steps 1 and 2 to ...

Page 10: ... the DXM s main menu scroll to System Info and then press ENTER twice to view the seven digit serial number at the bottom of the information list 3 Enter all seven digits into the DXM Serial entry field on Banner CDS 4 Verify that Configuration is set to Solutions and select Occupancy Total Count for the Kit Type This allows the Banner CDS application to automatically create Dashboard layouts and ...

Page 11: ...w profile 30 mm mounting hole 300 series stainless steel No fasteners included Optional Accessories Warning Indicator Segment SG TL70 Y Used with the TL70 Wireless Indicator Light Yellow indicator for Warning indication View Dashboard and Set Parameters After Banner CDS has created the site and detected the DXM Controller click on Go to Dashboard Go to Dashboard The Dashboard panel appears and ind...

Page 12: ...Banner Engineering Corp 9714 Tenth Avenue North Minneapolis Minnesota 55441 763 544 3164 1 888 373 6767 www bannerengineering com 2020 Banner Engineering Corp Mpls MN USA 219271 Rev A ...

Reviews: