June 23, 2023
T30RW R-GAGE Washdown Radar Sensor Instruction Manual
15
Advanced Target
Minimum Active Sensing Range
: Sensor ignores anything from the face of the sensor to this defined range.
Maximum Active Sensing Range
: Sensor ignores anything past this defined range.
Measurement Hold: A rate of change filter to smooth the output and reduce chatter. For more information,
see
Using Measurement Hold Example
Hold Time: The period of time the sensor holds its last measurement and output status if the measurement changes
more than the
Maximum Distance Increase
or the
Maximum Distance Decrease
. Available when
Measurement Hold
is
set to enabled.
Maximum Distance Increase: The allowed limit the measurement can increase, or move farther away from the sensor,
before initiating the
Measurement Hold
. Setting this to zero disables it. Available when
Measurement Hold
is set to
enabled.
Maximum Distance Decrease: The allowed limit the measurement can decrease, or move closer to the sensor, before
initiating the
Measurement Hold
. Setting this to zero disables it. Available when
Measurement Hold
is set to enabled.
Sensor Polarity
Define the output and remote input signal type.
Sensor Lockout
Remote Input (Gray Wire)
: Enable or disable the remote input wire.
Analog Tab
The following are the parameters on the
Analog
tab on the
Sensor Settings
pane. This tab is available for analog models.
Slope—Current-Sourcing Models
Positive
Slope
Near
Window
Far
Window
Analog Output (mA)
20
4
The analog current output tracks slightly beyond
Slope—Voltage-Sourcing Models, 0 V to 10
V
Positive
Slope
Near
Window
Far
Window
Analog Output (V DC)
10
0
The analog current output tracks slightly beyond the
upper window limit (up to 10.2 V)
Slope—Voltage-Sourcing Models, 0.5 V to
4.5 V
Positive
Slope
Near
Window
Far
Window
Analog Output (V DC)
4.5
0.5
The analog current output tracks slightly beyond
each window limit (0V - 5V)
Analog Span
Define the outer limits of the analog range. This can be used to create a positive or negative slope.
Analog output options:
Current: 4 mA to 20 mA
Voltage: 0 V to 10 V or 0.5 V to 4.5 V
Output
Loss–of–Signal
: Sets the Analog Output value used by the sensor during a loss of signal. When a signal is restored,
measurement resumes.
Hold Last Value—The Analog Output holds the last value indefinitely during a loss of signal.
3.5 mA (0 V)—The Analog Output switches to this value 2 seconds after a loss of signal. For Voltage models, this is 0
V. (Default)
20.5 mA (10.5 V/5 V)—The Analog Output switches to this value 2 seconds after a loss of signal. For Voltage models,
this is 10.5 V.
Averaging: Use this menu to set the number of measurements that are averaged together for the analog output.
Increasing the averaging improves repeatability but increases the total response speed. The default is 1. The filter can be
set to 1, 2, 4, 8, 16, 32, 64, or 128. The total response time is show under Response Time.
© Banner Engineering Corp.
Summary of Contents for T30RW
Page 4: ...Blank page 4...
Page 8: ...Blank page 8...
Page 18: ...Blank page 18...
Page 28: ...Blank page 28...
Page 34: ...Blank page 34...
Page 36: ...Blank page 36...
Page 40: ...Blank page 40...
Page 43: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...