General

2.4 GHz Compliance

FCC ID UE300DX80-2400 - This device complies with FCC
Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05)
IC: 7044A-DX8024

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

Link Timeout

Gateway: Configurable via User Configuration Tool (UCT)
software
Node: Defined by Gateway

Radio range is with the 2 dB antenna that ships with the product. High-
gain antennas are available, but the range depends on the environment
and line of sight. To determine the range of your wireless network, perform
a Site Survey.

Interface

Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD

Wiring Access

Four PG-7, One 1/2-inch NPT, One 5-pin Euro-style male
connector

Inputs

Environmental

Discrete Inputs

Rating: See control drawing
Sample/Report Rates: DIP switch configurable

Discrete Input ON Condition

PNP: Greater than 8V
NPN: Less than 0.7V

Discrete Input OFF Condition (DX99 Models)

PNP: Less than 4.5V
NPN: Greater than 2.2V or open

Analog Input Rating (mA Models)

Rating for 4 to 20 mA models: 24 mA
Impedance: 20 Ohms
Analog Input 1 Sample/Report Rates: DIP switch configura-
ble
Analog Input 2 Sample/Report Rates: 1 second / 16 seconds
Accuracy: 0.1% of full scale +0.01% per °C
Resolution: 12-bit

Analog Input Rating (V Models)

Rating for 0 to 10V models: 10V
Impedance: 20 Ohms
Analog Input 1 Sample/Report Rates: DIP switch configura-
ble
Analog Input 2 Sample/Report Rates: 1 second / 16 seconds
Accuracy: 0.25% of full scale +0.01% per °C
Resolution: 12-bit

Ratings

IEC IP67, NEMA 4x

Operating Conditions

Operating Temperature: −40 to +70 °C
Operating Humidity: 95% max. relative (non-condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz (EN61000-6-2)

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

To verify the analog input's impedance, use an Ohm meter to measure the
resistance between the analog input terminal (AIx) and the ground (GND)
terminal.
Refer to the 

SureCross DX80 Wireless I/O Network Product Manual

 (p/n

132607) for installation and waterproofing instructions. Operating the devi-
ces at the maximum operating conditions for extended periods can short-
en the life of the device.

Certifications

DX99 Polycarbonate Housings

CSA: Class I, Division 1, Groups A, B, C, D (Ex ia IIC / AEx ia IIC T4 ) Certificate: CSA 2008243

LCIE/ATEX: Zone 0 (Category 1G), Temperature Class T4 (II 1 G / Ex ia IIC T4) Certificate: LCIE 08 ATEX 6098 X

Notes: Special Conditions for Safe Use imposed by Intrinsic Safety Certificate LCIE 08 ATEX 6098 X: Ambient temperature range is
-40°C to +70°C. SureCross

®

 DX99 FlexPower devices can only be connected to Intrinsically Safe certified equipment or simple appara-

tus as defined by EN 60079-11. All connected equipment must comply with the Entity Parameters (Safety Parameters) listed in the 

Con-

trol Drawings

 (p/n 141513). The device must only use a lithium battery manufactured by XENO, type XL-205F.

SureCross DX99 FlexPower Node (Polycarbonate Housing)

 

 

P/N 142496 Rev. F

www.bannerengineering.com - tel: 763-544-3164

7

Summary of Contents for SureCross DX99 FlexPower Series

Page 1: ...nstalled in accordance with the National Electrical Code the Canadian Electrical Code or applicable local codes regulations Model 0 to 20 mA Frequency Boost Voltage Inputs and Outputs DX99N9X2S2N0M2X0...

Page 2: ...all your wireless sensor network components If installation instructions are not included in this datasheet refer to the product manual for detailed installation instructions For additional informatio...

Page 3: ...ch settings for this device are all in the OFF position Analog Configuration Switch 2 OFF 10V Boost Models For analog configuration DIP switch 2 is in the OFF position factory default Analog configura...

Page 4: ...minutes ON OFF ON Sample Report Rate 30 minutes ON ON OFF Modbus or UCT configured overrides DIP switches ON ON ON Analog IN 2 Discrete 1 and Discrete 2 are not powered from switched power terminals...

Page 5: ...lexPower applications setting the report rate to a slower rate extends the battery life Warm Up Time The warm up time defines how long the device must power up the sensor before a stable sensor readin...

Page 6: ...LCD remains on for an additional minute after the radio enters storage mode After a device has entered storage mode you must wait one minute before waking it During normal operation the SureCross rad...

Page 7: ...t Rates 1 second 16 seconds Accuracy 0 25 of full scale 0 01 per C Resolution 12 bit Ratings IEC IP67 NEMA 4x Operating Conditions Operating Temperature 40 to 70 C Operating Humidity 95 max relative n...

Page 8: ...ineering Corp if the destination country is not on this list Violating Warnings The manufacturer does not take responsibility for the violation of any warning listed in this document Make no modificat...

Reviews:

Related manuals for SureCross DX99 FlexPower Series