Banner RP-LS42F LE Series Instruction Manual Download Page 9

Dimensions

Figure 14. RP-LS42F..L Models

42.5 mm

(1.67")

45.0 mm

(1.77")

78.3 mm

(3.08")

5.0 mm

(0.20")

124.0 mm

(4.88")

224.0 mm

(8.82")

30.0 mm
(1.18")

Figure 15. RP-LS42F-xxLF Models

78.3 mm

(3.08")

265 mm
(10.43")

317 mm
(12.48")

Accessories for RP-LS42F..

EZ-LIGHTS

See datasheet p/n 171472 for additional information.

Model

Number of Colors

Color

Connection

Quantity

Product Image

SI-K30LGRX7P

2

GREEN/RED indication

130 mm (5 in) flying
lead wires

1 each

Ø30

27

M20 X 1.5

SI-K30LRXX7P

1

RED indication

1 each

SI-K30LYRX7P

2

YELLOW/RED indication

1 each

Cable Gland

Model

Size

For Cable Diameter

Dimensions

Used With

SI-QS-CGM20

M20 × 1.5 Plastic

5.0 to 12.0 mm (0.20 to
0.47 inches)

M20 x 1.5

25.0 mm

(0.98")

37.0 mm

(1.46")

RP-LS42 Rope Pull Switch
SI-GL42 Safety Interlock Switch
SI-LS31 Safety Interlock Switch
SI-LS42 Safety Interlock Switch
SI-LS100 Safety Interlock Switch
SI-QS90 Safety Interlock Switch

Rope Pull Emergency Stop Switches

 

 

P/N 67709 Rev. C

www.bannerengineering.com - Tel: + 1 888 373 6767

9

Summary of Contents for RP-LS42F LE Series

Page 1: ...22 34 42 13 21 33 41 Run 14 22 34 42 13 21 33 41 Pull Break Note This symbol for a positive opening safety contact IEC 60947 5 1 is used in the switching diagram to identify the point in actuator tra...

Page 2: ...cable pull The rope or cable pull as well as any flags or markers must be colored RED The rope or cable pull must have the capability to react to a force in any direction This requires a spring at the...

Page 3: ...mbly RPA S4 1 or RPA S6 1 eye bolt to an anchor that is solid and stationary and can withstand the constant tension and pull of the rope Do not exceed the maximum length for the specific switch 3 For...

Page 4: ...edian position to allow for adjustment in both directions b Attach the prepared turnbuckle to the rope using a thimble clamp loop Keep the rope s PVC cover intact along its complete length except wher...

Page 5: ...e accomplished by pulling excess rope through the clamp until the tension indicator is approximately centered and then re tightening the clamp It is recommended that tensioning be accomplished at a me...

Page 6: ...s to the terminals 1 Insert the screwdriver blade flat 2 5 mm into the slot next to the desired wiring terminal 2 Twist the screwdriver blade 45 in the slot to open the terminal jaws insert the wire 6...

Page 7: ...series Never connect the contacts of multiple switches in parallel Individually actuate engage each device then release or re arm and reset the safety module This allows the module to check each switc...

Page 8: ...Type gG Recommend external fusing or overload protection B10d 1 x 105 cycles at DC 13 24 V Ie2 0 1 A Mechanical Life 1 x 105 switching cycles maximum according to IEC 60947 5 5 Wire Connections 8 x ca...

Page 9: ...ion 130 mm 5 in flying lead wires 1 each 30 27 M20 X 1 5 SI K30LRXX7P 1 RED indication 1 each SI K30LYRX7P 2 YELLOW RED indication 1 each Cable Gland Model Size For Cable Diameter Dimensions Used With...

Page 10: ...8 ft 3 mm steel wire rope with 0 5 mm red PVC jacket unterminated RPA C2 20 20 m 65 6 ft RPA C2 40 40 m 131 2 ft RPA C2 50 50 m 164 0 ft RPA C2 80 80 m 262 4 ft Model Quantity Description Thimble RPA...

Page 11: ...Turnbuckle Each RPAK C2SBP 1 0 5 m 1 5 ft 2 2 RPAK CH2 10 10 m 32 8 ft 4 4 3 RPAK CHP2 10 4 4 3 3 RPAK CH2 10 TA 4 4 3 1 RPAK CHP2 10 TA 4 4 3 3 1 RPAK CH2 20 20 m 65 6 ft 4 4 6 RPAK CHP2 20 4 4 6 6...

Page 12: ...IVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF...

Reviews: