Instruction Manual

RP-LS42F-xxL and xxLF Series 42 mm Latching Switches with Rope/Cable Actuators

 Positive-opening safety contacts (IEC 60947-5-1), not dependent upon springs

Both safety contacts latch open when rope is pulled, broken, or if tension is reduced;

requires manual reset (IEC 60947-5-5)

Compliant with ANSI B11.19, NFPA 79, IEC/EN 60204-1 and ISO 13850 Emergency Stop

requirements

Heavy-duty thermoplastic housing (polyamide), rated IP67, suitable for demanding industrial

environments; insulated device 

Innovative quick-connect design provides quick, easy rope fixing and tensioning on RP-

LS42F-..LF models

Rope spans of 25 m (82 ft), 37.5 m (125 ft), and 75 m (245 ft), depending on model

Monitoring contacts operate opposite the safety contacts, for monitoring by another device

or interfaced with EZ-LIGHT

®

 indicators

Tension indicator window indicates proper rope tension for operation or safety contacts

latched open (the rope pull or the E-stop button is actuated)

Models

Maximum Rope Length / Force

Rope

Connection

E-Stop

Button

75 m (246.1 ft) / 300 N

38 m (124.7 ft) / 175 N

25 m (82.0 ft) / 100 N

RP-LS42F-75L

RP-LS42F-38L

RP-LS42F-25L

Ring

No

RP-LS42F-75LF

RP-LS42F-38LF

RP-LS42F-25LF

Turnbuckle

No

Figure 1. Contact State

14
22
34
42

13
21
33
41

Run

14
22
34
42

13
21
33
41

Pull / Break

Note: 

This symbol 

 for a positive-opening safety

contact (IEC 60947-5-1) is used in the switching diagram

to identify the point in actuator travel where the normally-

closed safety contact is fully open.

Figure 2. Switching Diagram

0 mm

80N / 140N / 240N

100N / 175N / 300N

60N / 105N / 180N

Operating point ± 0.5 mm
Actuating force ± 15%

Latch

Latch

Monitoring

Safety

Monitoring

Safety

-5 mm

+3.5 mm

+4.3 mm

+5 mm

-4.3 mm

-3.5 mm

13-14

21-22

33-34

41-42

Contacts: 

Open 

Closed 

Transition

Important... Read this before proceeding!

The user is responsible for satisfying all local, state, and national laws,

 rules, codes, and regulations relating to the use of this

product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation,

and maintenance instructions. Please contact a Banner Applications Engineer with any questions regarding this product.

The user is responsible

 for making sure that all machine operators, maintenance personnel, electricians, and supervisors are

thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the

machinery it controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar

Rope Pull Emergency Stop Switches

 

 

Original Document

67709 Rev. C

4 November 2021

67709

Summary of Contents for RP-LS42F LE Series

Page 1: ...22 34 42 13 21 33 41 Run 14 22 34 42 13 21 33 41 Pull Break Note This symbol for a positive opening safety contact IEC 60947 5 1 is used in the switching diagram to identify the point in actuator tra...

Page 2: ...cable pull The rope or cable pull as well as any flags or markers must be colored RED The rope or cable pull must have the capability to react to a force in any direction This requires a spring at the...

Page 3: ...mbly RPA S4 1 or RPA S6 1 eye bolt to an anchor that is solid and stationary and can withstand the constant tension and pull of the rope Do not exceed the maximum length for the specific switch 3 For...

Page 4: ...edian position to allow for adjustment in both directions b Attach the prepared turnbuckle to the rope using a thimble clamp loop Keep the rope s PVC cover intact along its complete length except wher...

Page 5: ...e accomplished by pulling excess rope through the clamp until the tension indicator is approximately centered and then re tightening the clamp It is recommended that tensioning be accomplished at a me...

Page 6: ...s to the terminals 1 Insert the screwdriver blade flat 2 5 mm into the slot next to the desired wiring terminal 2 Twist the screwdriver blade 45 in the slot to open the terminal jaws insert the wire 6...

Page 7: ...series Never connect the contacts of multiple switches in parallel Individually actuate engage each device then release or re arm and reset the safety module This allows the module to check each switc...

Page 8: ...Type gG Recommend external fusing or overload protection B10d 1 x 105 cycles at DC 13 24 V Ie2 0 1 A Mechanical Life 1 x 105 switching cycles maximum according to IEC 60947 5 5 Wire Connections 8 x ca...

Page 9: ...ion 130 mm 5 in flying lead wires 1 each 30 27 M20 X 1 5 SI K30LRXX7P 1 RED indication 1 each SI K30LYRX7P 2 YELLOW RED indication 1 each Cable Gland Model Size For Cable Diameter Dimensions Used With...

Page 10: ...8 ft 3 mm steel wire rope with 0 5 mm red PVC jacket unterminated RPA C2 20 20 m 65 6 ft RPA C2 40 40 m 131 2 ft RPA C2 50 50 m 164 0 ft RPA C2 80 80 m 262 4 ft Model Quantity Description Thimble RPA...

Page 11: ...Turnbuckle Each RPAK C2SBP 1 0 5 m 1 5 ft 2 2 RPAK CH2 10 10 m 32 8 ft 4 4 3 RPAK CHP2 10 4 4 3 3 RPAK CH2 10 TA 4 4 3 1 RPAK CHP2 10 TA 4 4 3 3 1 RPAK CH2 20 20 m 65 6 ft 4 4 6 RPAK CHP2 20 4 4 6 6...

Page 12: ...IVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF...

Reviews: