June 22, 2023
LTF Time Of Flight Laser Distance Sensor Instruction Manual
37
Navigate
:
MENU
›
MEASURE
›
Trigger
Remote Input
: Not available
Default
: Sample
Trigger
Description
Sample
The current distance at the time of the trigger event. (Default) The Analog Output tracks the sam-
ple values during the measuring period.
Average
The average distance since the last trigger event.
Maximum (Max)
The maximum distance since the last trigger event.
Minimum (Min)
The minimum distance since the last trigger event.
Range
The difference between the maximum and minimum distance since the last trigger event. For ad-
ditional information on the Range measurement behavior when the maximum or minimum dis-
tance is outside of the taught setpoints, see
.
TrackMax
The maximum distance since the last trigger event. The Analog Output tracks new maximum val-
ues during the measurement period.
TrackMin
The minimum distance since the last trigger event. The Analog Output tracks new minimum val-
ues during the measurement period.
Sample
Active
Sample
Inactive
(t)
Input
Signal
Hold
Measurement
Hold
Measurement
Measuring Period
Measuring Period
Average
Average
(t)
Measuring Period
Measuring Period
Active
Inactive