![Banner iVu Plus User Manual Download Page 30](http://html1.mh-extra.com/html/banner/ivu-plus/ivu-plus_user-manual_3759257030.webp)
Command
Group
Item
Description
Get
History
MaxInspectionTime
This value indicates the maxi-
mum (slowest) inspection time
for the active inspection. This
value is cleared (reset) whenev-
er history is cleared. This value
is cleared (reset) when the de-
vice starts up or is rebooted.
Get
History
MinBarcodeCount
This value indicates the mini-
mum number of barcodes read
for the active inspection This
value is cleared (reset) whenev-
er history is cleared. This value
is cleared (reset) when the de-
vice starts up or is rebooted.
Get
History
MaxBarcodeCount
This value indicates the maxi-
mum number of barcodes read
for the active inspection This
value is cleared (reset) whenev-
er history is cleared. This value
is cleared (reset) when the de-
vice starts up or is rebooted.
Do
History
Clear
This command clears all history
fields for the active inspection.
History values include pass
count, fail count, execution
times and tool specific history
values. This command can be
performed using the sensor's
touchscreen.
Examples
>>
get history passed
\x0D\x0A
<<
OK\x0D\x0A
<<
13\x0D\x0A
>>
get history startframenumber
\x0D\x0A
<<
OK\x0D\x0A
<<
3\x0D\x0A
>>
do history clear
\x0D\x0A
<<
OK\x0D\x0A
3.4 Inspection Command Group
Command
Group
Item
Description
Get
Inspection
Status
This status of the most recent
inspection either Pass, Fail, or
Idle (no triggers).
iVu Plus BCR Communications User's Guide
30
www.bannerengineering.com - tel: 763-544-3164
Online Only - rev. A