![Banner iVu Plus User Manual Download Page 25](http://html1.mh-extra.com/html/banner/ivu-plus/ivu-plus_user-manual_3759257025.webp)
Examples
>>
get info companyname
\x0D\x0A
<<
OK\x0D\x0A
<<
"Banner Engineering Corp."\x0D\x0A
>>
get info bootnumber
\x0D\x0A
<<
OK\x0D\x0A
<<
42\x0D\x0A
>>
get info uptimer
\x0D\x0A
<<
OK\x0D\x0A
<<
4:42:42:324\x0D\x0A
3.4 System Command Group
Command
Group
Item
Description
Do
System
Reboot
Reboots the sensor. Pre-empts
other commands except Save.
Do
System
Save
Saves inspection and configura-
tion parameters. Blocks until fin-
ished. Should be used sparing-
ly.
Examples
>>
do system save
\x0D\x0A
<<
OK\x0D\x0A
3.4 Status Command Group
Command
Group
Item
Description
Get
Status
Ready
Flag indicating whether the sys-
tem is ready to trigger (true) or
busy (false)
Get
Status
SystemError
Flag indicating whether a sys-
tem error is active (true) or
cleared (false)
Do
Status
ClearSystemError
Clears the system error LED
and sets the internal flag to
false.
Examples
>>
get status ready
\x0D\x0A
<<
OK\x0D\x0A
<<
True\x0D\x0A
>>
get status systemerror
\x0D\x0A
iVu Plus BCR Communications User's Guide
Online Only - rev. A
www.bannerengineering.com - tel: 763-544-3164
25