Required Overcurrent
Protection
WARNING: Electrical
connections
must be made by
qualified
personnel in accordance with local and
national
electrical codes and
regulations.
Overcurrent
protection
is required to be provided by end product
application
per the supplied table.
Overcurrent
protection
may be provided with external fusing or via Current
Limiting,
Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For
additional
product support, go to
http://www.bannerengineering.com
.
Supply Wiring (AWG)
Required Overcurrent
Protection
(Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5