3. If the
fiber
optic
array is contaminated enough that the auto
compensation
tracking algorithm cannot
sufficiently
adjust the
thresholds to ensure reliable
detection
4. If the
fiber
optic
array is blocked for more than 2 seconds
Return the system to normal
operation
by cleaning the
fiber
optic
array and performing a Window SET to reset the clear-state light level
(see
on page 19).
Complementary Programming
When CH2 is selected for Comp (Complementary)
operation,
its output always switches to the opposite state of CH1.
3.2.2 TEACH
Selection
The DF-G3 can be programmed for one of the following TEACH/SET methods:
• Two-Point TEACH
• Dynamic TEACH
• Window SET
• Light SET
• Dark SET
•
Calibration
SET
Note: A TEACH
Selection
must be selected by programming before TEACH/SET methods can be used.
3.2.3 Response Speed
The DF-G3 can be programmed for one of the following Response Speeds:
Description
Response
Speed
Repetition
Period
Repeatability
Cross-Talk
Avoidance
Energy
Efficient
Light
Resistance
Maximum Range,
Red3
Maximum Range,
IR8504
High Speed
500 µs
100 µs
100 µs
No
No
1200 mm
2400 mm
Fast
1000 µs
100 µs
150 µs
Yes
No
1500 mm
3000 mm
Standard
2 ms
100 µs
180 µs
Yes
Yes
1500 mm
3000 mm
Long Range
8 ms
100 µs
180 µs
Yes
Yes
1950 mm
3900 mm
Extra Long Range
24 ms
100 µs
180 µs
Yes
Yes
3000 mm
6000 mm
3.2.4
Offset
Percent
The
Offset
Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are
positioned
a programmable %
offset
from the taught
condition.
The allowable range is 5% minimum to 95% maximum for all response speeds.
The
offset
percent can also be programmed to Minimum
Offset
. This allows the DF-G3 to set the threshold(s) as close
as possible to the presented
condition,
but
still
provide for reliable sensing.
Note:
Offset
Percent MUST be programmed to Minimum
Offset
for Dark SET to accept
conditions
of no signal (0 counts).
3.2.5 Auto Thresholds
Auto Thresholds can be programmed to be ON/OFF. The Auto Thresholds algorithm
continuously
tracks slow changes in the taught
condition(s),
and
optimizes
the threshold(s) to provide for reliable sensing. For Two-Point and Dynamic TEACH, the algorithm
optimizes
the threshold to be centered between the light and dark
conditions.
For Window, Light, and Dark SET, the algorithm
optimizes
the
threshold(s) to maintain the programmed
Offset
Percent from the taught
condition.
•
After
programming Auto Thresholds to ON, it is highly recommended to re-perform the TEACH/SET method
• Manual Adjustments are disabled when Auto Thresholds are ON
• Auto Thresholds are
automatically
disabled in
Calibration
SET (see
on page 23)
• Severe
contamination/changes
in the taught
condition
can prevent the Auto Thresholds algorithm from
optimizing
the
threshold(s). If this occurs, the DF-G3 enters a Threshold Alert or Threshold Error state. See
on page 25 for
more
explanation.
3 Excess gain = 1 (high
sensitivity),
opposed mode sensing. PIT46U
plastic
fiber
used for visible LED models.
4 Excess gain = 1 (high
sensitivity),
opposed mode sensing. IT.83.3ST5M6 glass
fiber
used for IR models.
DF-G3 Long Range Expert
™
Dual Display Fiber
Amplifier
12
www.bannerengineering.com - Tel: 763.544.3164