![Banner D10 Series Manual Download Page 17](http://html1.mh-extra.com/html/banner/d10-series/d10-series_manual_3708606017.webp)
1. Access SETUP Mode.
Method
Action
Result
Push Button18
Press and hold both buttons concurrently for > 2
seconds.
The indicator arrow icon 1 is ON red.
Remote Input19
Double-pulse the remote line.
T
T
T
2. Select Light/Dark Operate.
Method
Action
Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to save selection and advance to
"OFF-Delay."
Light Operate
•
Display flashes "lo"
•
L icon
Dark Operate
•
Display flashes "do"
•
D icon
Remote Input
a. Double-pulse remote line to toggle between
selections.
b. Single-pulse remote line to save selection and
advance to "OFF-Delay."
T
T
T
T
3. Select OFF-Delay Timing Enable.
Method
Action
Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to save selection and advance to
"Display."
Off (No OFF-Delay)
•
"t 0"
•
Clock icon OFF
2 to 100 ms OFF-Delay
•
“t 2,” “t 5,” “t 10,” “t 15,” “t
20,” “t 30,” “t 40,” “t 60,” “t
80,” or “t100”
•
Clock icon ON
Remote Input
a. Double-pulse remote line to toggle between
selections.
b. Single-pulse remote line to save selection and
advance to "Display."
T
T
T
T
4. Select Display Parameters.
Method
Action
Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to save selection and advance to
"Power/Speed."
Raw Signal Value
"1234"
Percent of excess signal
"123P"
Remote Input
a. Double-pulse remote line to toggle between
selections.
b. Single-pulse remote line to save selection and
advance to "Power/Speed."
T
T
T
T
5. Select Speed and Power Combination.
18 0.04 seconds
≤
"Click"
≤
0.8 seconds
19 0.04 seconds
≤
T
≤
0.8 seconds
D10 Expert
™
– Dual Discrete Outputs
P/N 64154 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
11