Banner D10 Expert Quick Start Manual Download Page 9

D10 

Expert™ Discrete Output with Bargraph Display

Specifications

Standard Sensors

Models with Bussable Power

Sensing Beam

660 nm visible red or 525 nm visible green, 

depending on model

660 nm visible red

Supply Voltage

10 to 30V dc (10% max. ripple) @ less than 45 
mA exclusive of load

12 to 30V dc (10% max. ripple) @ less than 45 mA 
exclusive of load

Supply Protection Circuitry

Protected against reverse polarity, over voltage, and transient voltages

Delay at Power Up

200 milliseconds max.; outputs do not conduct 

during this time

850 milliseconds max.; outputs do not conduct during this 

time

Output Configuration

Bipolar; 1 current sourcing (PNP) and 1 current 

sinking (NPN) 

Main units:

 Bipolar; 1 current sourcing (PNP) and 1 

current sinking (NPN) 
Sub-units: 1 current sourcing (PNP) or 1 current sinking 
(NPN) output, depending on model

Output Rating

150 mA max. load @ 25° C (derate 1 mA per °C 

increase) 
OFF-state leakage current: 

< 5 µA at 30V dc

 

ON-state saturation voltage: 
  NPN:

 < 200 mV @ 10 mA; 1V @ 150 mA load

 

  PNP:

 < 1V @ 10 mA; 1.5V @ 150 mA load

 

100 mA max. load (derate 1 mA per °C above 30° C)

 

OFF-state leakage current: 

< 5 µA at 30V dc

 

ON-state saturation voltage: 
  NPN:

 < 1.5V    

 

  PNP:

 < 2V   

 

Supply 15V or more:

 up to 16 units with 100 mA outputs

 

Less than 15V supply (9 m cable):  
  up to 4 units with 100 mA outputs   

  up to 8 units with 50 mA outputs

Output Protection

Protected against output short-circuit, continuous overload, transient over-voltages, and false pulse on power up

Output Response Time

500 microseconds (normal mode) or 200 microseconds (high-speed mode)

Repeatability

100 microseconds (normal mode) or 66 microseconds (high-speed mode)

Adjustments

2 push buttons and remote wire

 

• 

Expert

-style configuration (Static and Dynamic TEACH, and Window SET)

 

•  Manually adjust (+/–) sensitivity (from push buttons only)

 

•  LO/DO, OFF-delay, and response speed configurable (from push buttons or remote wire)

 

•  Push button lockout (from remote wire only)

Factory Default Settings: 

Light Operate, Normal Speed, No Delay

Indicators

8-segment red bargraph:  

Light-to-dark signal difference relative to taught condition (Window SET)

 

Sensing contrast (Static or Dynamic TEACH)

Green Status Indicators:

 LO, DO, High Speed (HS), and OFF-Delay

 

Green LED: Power ON 
Yellow LED: Output conducting

Construction

Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover

Environmental Rating

IEC IP50, NEMA 1

Connections

PVC-jacketed 2 m or 9 m (6.5' or 30') 6-wire 
integral cable or integral 6-pin Pico-style quick-

disconnect

Main units:

 PVC-jacketed 2 m or 9 m (6.5' or 30') 

 

  5-wire integral cable

 

Sub-units:

 PVC-jacketed 2 m or 9 m (6.5' or 30') 

 

  2-wire integral cable

Operating Conditions

Temperature: 

 -10° to +55° C (+14° to 131° F)

 

Storage: 

 -20° to +85° C (-4° to +185° F)

 

Relative Humidity:

  90% @ 55° C (non-condensing)

Certifications

                 

(CE approval is pending for models with bussable power)

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for D10 Expert

Page 1: ...alk avoidance routine for two sensors in Normal mode Selectable high speed HS mode option for 200 microsecond response Extreme configuration flexibility via push buttons or a remote input wire Easy se...

Page 2: ...une the thresholds see page 8 Two push buttons Dynamic and Static or the remote wire may be used to access and set the sensing parameters Sensor sensitivity may be configured using any of three method...

Page 3: ...emote Line 0 04 seconds T 0 8 seconds Result Access TEACH Mode Press and hold Static button 2 seconds No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Status LEDs...

Page 4: ...t OFF Output ON Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Darkest no signal Most Light saturated signal Output OFF Output ON Position adjusted by...

Page 5: ...remote line Window Accepted Power LED ON Bargraph 2 indicators flash together to show Window accepted Sensor returns to RUN mode with new settings Window Unacceptable Power LED OFF Bargraph 1 3 5 7 fl...

Page 6: ...tons Manual Adjust Recommended for applications where only one condition is known for example a stable light background with varying darker targets A single sensing condition is presented and the sens...

Page 7: ...han the threshold condition causes the output to change state Threshold position is adjustable using the and buttons Manual Adjust Recommended for applications where only one condition is known for ex...

Page 8: ...5x T 0 8 seconds 2 seconds T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button 0 04 seconds Click 0 8 seconds Remote Line 0 04 seconds T 0 8 seconds Result Access SETUP Mode Press and...

Page 9: ...against output short circuit continuous overload transient over voltages and false pulse on power up Output Response Time 500 microseconds normal mode or 200 microseconds high speed mode Repeatability...

Page 10: ...mm 0 08 1 mm 0 04 0 0 0 5 mm 1 0 mm 1 5 mm 0 5 mm 1 0 mm 1 5 mm 0 DISTANCE BEAM WIDTH BEAM WIDTH PBT46U PBT66U PBT26U Opposed Mode Green Beam Models Diffuse Mode Performance based on 90 reflectance w...

Page 11: ...2 Screws 2 Hex Nuts 2 Bracket Dimensions Bracket included with Standard Sensor Models 61 3 mm 2 42 68 1 mm 2 68 10 5 0 2 mm typ 0 41 14 5 mm 0 57 Mounting Bracket included with some models 35 9 mm 1...

Page 12: ...Brown 2 White 3 Blue 4 Black 5 Gray 6 Pink Not Used 6 Pin 6 Wire Pico 1 5 6 3 4 2 Quick Disconnect Cordsets Accessories SA DIN CLAMP Pair of metal DIN rail end stops slide onto DIN rail at either side...

Reviews: