D10
Expert™ Discrete Output with Bargraph Display
Figure 7. SETUP mode
SETUP Mode
SETUP mode is used to change sensor output response for:
• Light or Dark operate
• 30-millisecond pulse stretcher (OFF-delay), if required.
• 200
µs high-speed response
If SETUP mode configuration is interrupted and remains inactive for 60 seconds, the sensor
returns to RUN mode with the most recent settings (i.e., exits and saves current selection).
SET
UP mode operates in the “background,” while the outputs are active; changes are
updated instantly.
dynamic
static
8
4
6
5
3
2
1
7
DO
LO
HS
SETUP
Status
Indicators
Press
and hold both
push buttons
> 2 seconds
to access
SETUP mode
{
Manual Adjust
Manual Adjust is used during RUN mode and is accomplished via the push buttons only. Its behavior depends on whether a switching
threshold or a sensing window is used.
Switching Threshold:
• Fine-tunes sensing sensitivity
• Press “+” to increase; press “-” to decrease
Sensing Window:
• Adjusts sensing window size (tolerance) for the single-point target condition
• Press “+” to increase; press “-” to decrease
The lighted bargraph LEDs move to reflect the increase or decrease.
Push Button Disable
In addition to its configuration function, the remote input may be used to disable the push buttons for security. Disabling the push
buttons prevents undesired tampering with the configuration settings. Connect the gray wire of the sensor as described on page 2, and
four-pulse to either enable or disable the push buttons:
T
T
T
1x
2x
3x
4x
5x
6x
7x
T
0.8 seconds
> 2 seconds
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T T
B_028256
Push Button
0.04 seconds ≤ “Click” ≤ 0.8 seconds
Remote Line
0.04 seconds ≤ T ≤ 0.8 seconds
Result
Access
SETUP
Mode
• Press and hold both push
buttons > 2 seconds.
• Double-pulse remote
line.
• Green Power LED turns OFF.
• Output LED remains active.
• Icons continue to display
current setup.
• Bargraph turns OFF.
Select
Setting
Combination
• Click either push button until
LEDs show desired settings.
• Pulse the remote line
until LEDs show desired
settings.
NOTE: Double-pulsing the
remote line will cause the
setting to “back up” one step.
Sensor toggles through eight setting combinations, in the
following order:
LO - Normal Speed - No Delay (default)
DO - Normal Speed - No Delay
LO - High Speed -
No Delay
DO - High Speed -
No Delay
LO - Normal Speed - Delay
DO - Normal Speed - Delay
LO - High Speed -
Delay
DO - High Speed -
Delay
Return
to
RUN
Mode
• Press and hold both push
buttons > 2 seconds.
• Hold remote line low
> 2 seconds.
• Green Power LED turns ON.
• Sensor returns to RUN mode
with new settings.
or
or
or
dynamic
static
8
4
6
5
3
2
1
7
DO
LO
HS
T
T
T
1x
2x
3x
4x
5x
6x
7x
T
0.8 seconds
> 2 seconds
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T T
B_028256
T
T
T
1x
2x
3x
4x
5x
6x
7x
T
0.8 seconds
> 2 seconds
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T T
B_028256
T
T
T
1x
2x
3x
4x
5x
6x
7x
T
0.8 seconds
> 2 seconds
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T T
B_028256
dynamic
static
8
4
6
5
3
2
1
7
DO
LO
HS
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]