Banner D10 Expert Quick Start Manual Download Page 11

D10 

Expert™ Discrete Output with Bargraph Display

Dimensions

10.0 mm

(0.39")

35.1 mm

(1.38")

10.0 mm

(0.39")

15.2 mm

(0.60")

2x C'sink
ø8.0 mm (0.31")
3.2 mm (0.13") deep
ø4.4 mm (0.18") thru
max. torque 10 in./lbs.

2x 3.5 mm
(0.14")

5.0 mm

(0.20")

8.6 mm
(0.34")

25.4 mm

(1.00")

16.0 mm

(0.63")

2 x ø3.3 mm (0.13") max. torque 6 in./lbs. 

2x ø3.2 mm (0.13") max. torque 6 in./lbs.

2.5 mm (0.10")

5.0 mm (0.20")

M3 Hardware included:
  Lock Washer (2)
  Flat Washer (2)
  Screws (2)
  Hex Nuts (2)

Bracket Dimensions (Bracket included with Standard Sensor Models)

61.3 mm

(2.42")

68.1 mm

(2.68")

10.5 ± 0.2 mm (typ.)
(0.41")

14.5 mm
(0.57")

Mounting Bracket

(included with some models)

35.9 mm

(1.41")

7.6 mm

0.30"

9.8 mm

(0.39")

Plastic Fiber

Emitter Port

Plastic Fiber

Receiver Port

Slides Up to

Release Fibers

61.3 mm

(2.42")

68.1 mm

(2.68")

Plastic Fiber

Emitter Port

Plastic Fiber

Receiver Port

10.5 ± 0.2 mm (typ.)
(0.41")

Mounting Bracket

(included)

Slides Up to

Release Fibers

35.9 mm

(1.41")

7.6 mm

0.30"

9.8 mm

(0.39")

Installing Fibers

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for D10 Expert

Page 1: ...alk avoidance routine for two sensors in Normal mode Selectable high speed HS mode option for 200 microsecond response Extreme configuration flexibility via push buttons or a remote input wire Easy se...

Page 2: ...une the thresholds see page 8 Two push buttons Dynamic and Static or the remote wire may be used to access and set the sensing parameters Sensor sensitivity may be configured using any of three method...

Page 3: ...emote Line 0 04 seconds T 0 8 seconds Result Access TEACH Mode Press and hold Static button 2 seconds No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Status LEDs...

Page 4: ...t OFF Output ON Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Darkest no signal Most Light saturated signal Output OFF Output ON Position adjusted by...

Page 5: ...remote line Window Accepted Power LED ON Bargraph 2 indicators flash together to show Window accepted Sensor returns to RUN mode with new settings Window Unacceptable Power LED OFF Bargraph 1 3 5 7 fl...

Page 6: ...tons Manual Adjust Recommended for applications where only one condition is known for example a stable light background with varying darker targets A single sensing condition is presented and the sens...

Page 7: ...han the threshold condition causes the output to change state Threshold position is adjustable using the and buttons Manual Adjust Recommended for applications where only one condition is known for ex...

Page 8: ...5x T 0 8 seconds 2 seconds T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button 0 04 seconds Click 0 8 seconds Remote Line 0 04 seconds T 0 8 seconds Result Access SETUP Mode Press and...

Page 9: ...against output short circuit continuous overload transient over voltages and false pulse on power up Output Response Time 500 microseconds normal mode or 200 microseconds high speed mode Repeatability...

Page 10: ...mm 0 08 1 mm 0 04 0 0 0 5 mm 1 0 mm 1 5 mm 0 5 mm 1 0 mm 1 5 mm 0 DISTANCE BEAM WIDTH BEAM WIDTH PBT46U PBT66U PBT26U Opposed Mode Green Beam Models Diffuse Mode Performance based on 90 reflectance w...

Page 11: ...2 Screws 2 Hex Nuts 2 Bracket Dimensions Bracket included with Standard Sensor Models 61 3 mm 2 42 68 1 mm 2 68 10 5 0 2 mm typ 0 41 14 5 mm 0 57 Mounting Bracket included with some models 35 9 mm 1...

Page 12: ...Brown 2 White 3 Blue 4 Black 5 Gray 6 Pink Not Used 6 Pin 6 Wire Pico 1 5 6 3 4 2 Quick Disconnect Cordsets Accessories SA DIN CLAMP Pair of metal DIN rail end stops slide onto DIN rail at either side...