Banner D10 Expert Quick Start Manual Download Page 1

D10 

Expert

– with Discrete Output and Bargraph Display

Advanced sensor for use with plastic fiber optics

 WARNING . . . 

Not To Be Used for Personnel Protection

Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.

These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A 
sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner 
Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.

Models

Features

•  Easy-to-read 8-segment light bar indicator for teach and signal strength readout, plus 

indicators for continuous readout of operating status (user configuration)

•  Easy-to-set automatic 

Expert-style configuration options include Static and Dynamic 

TEACH, and Window SET, plus manual adjustment for fine tuning 

•  Smart gain-control algorithm to maximize performance in low-contrast applications
•  Fast 500-microsecond sensing response with improved crosstalk avoidance routine

 

(for two sensors) in Normal mode

•  Selectable high-speed (HS) mode option for 200-microsecond response
• Extreme configuration flexibility via push buttons or a remote input wire
•  Easy selection of Light/Dark Operate (LO/DO), 30 ms pulse stretcher (OFF-delay), 

and response speed, via push buttons or a remote input wire

•  Visible red (660 nm) or visible green (525 nm) sensing beam, depending on model
• Sleek, ultra-slim 10 mm housing, mounts to standard 35 mm DIN rail

•  Models with bussable power provide simplified wiring of up to 16 sensors and feature 

improved temperature compensation for side-by-side mounting 

 U.S. Patent(s) issued or pending

* 9 m (30') cables are available by adding suffix

 “W/30” 

to the model number of any cabled sensor (e.g., 

D10BFP W/30). 

   A model with a QD connector requires a mating cordset (see page 12).

 

NOTE: See page 10 for performance curves.

Model

Description

Cable*

Outputs

Red Beam

Green Beam

D10BFP

D10BFPG

Standard sensor

2 m (6.5') Cable

Bipolar NPN/PNP

D10BFPQ

D10BFPGQ

6-pin Pico-style QD

Models with Bussable Power

D10B5FP

Main unit

2 m (6.5') Cable

Bipolar NPN/PNP

D10B2PFP

Sub-unit

2 m (6.5') Cable

Single PNP

D10B2NFP

2 m (6.5') Cable

Single NPN

Standard Model

Stack of Models with Bussable Power Feature

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for D10 Expert

Page 1: ...alk avoidance routine for two sensors in Normal mode Selectable high speed HS mode option for 200 microsecond response Extreme configuration flexibility via push buttons or a remote input wire Easy se...

Page 2: ...une the thresholds see page 8 Two push buttons Dynamic and Static or the remote wire may be used to access and set the sensing parameters Sensor sensitivity may be configured using any of three method...

Page 3: ...emote Line 0 04 seconds T 0 8 seconds Result Access TEACH Mode Press and hold Static button 2 seconds No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Status LEDs...

Page 4: ...t OFF Output ON Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Darkest no signal Most Light saturated signal Output OFF Output ON Position adjusted by...

Page 5: ...remote line Window Accepted Power LED ON Bargraph 2 indicators flash together to show Window accepted Sensor returns to RUN mode with new settings Window Unacceptable Power LED OFF Bargraph 1 3 5 7 fl...

Page 6: ...tons Manual Adjust Recommended for applications where only one condition is known for example a stable light background with varying darker targets A single sensing condition is presented and the sens...

Page 7: ...han the threshold condition causes the output to change state Threshold position is adjustable using the and buttons Manual Adjust Recommended for applications where only one condition is known for ex...

Page 8: ...5x T 0 8 seconds 2 seconds T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button 0 04 seconds Click 0 8 seconds Remote Line 0 04 seconds T 0 8 seconds Result Access SETUP Mode Press and...

Page 9: ...against output short circuit continuous overload transient over voltages and false pulse on power up Output Response Time 500 microseconds normal mode or 200 microseconds high speed mode Repeatability...

Page 10: ...mm 0 08 1 mm 0 04 0 0 0 5 mm 1 0 mm 1 5 mm 0 5 mm 1 0 mm 1 5 mm 0 DISTANCE BEAM WIDTH BEAM WIDTH PBT46U PBT66U PBT26U Opposed Mode Green Beam Models Diffuse Mode Performance based on 90 reflectance w...

Page 11: ...2 Screws 2 Hex Nuts 2 Bracket Dimensions Bracket included with Standard Sensor Models 61 3 mm 2 42 68 1 mm 2 68 10 5 0 2 mm typ 0 41 14 5 mm 0 57 Mounting Bracket included with some models 35 9 mm 1...

Page 12: ...Brown 2 White 3 Blue 4 Black 5 Gray 6 Pink Not Used 6 Pin 6 Wire Pico 1 5 6 3 4 2 Quick Disconnect Cordsets Accessories SA DIN CLAMP Pair of metal DIN rail end stops slide onto DIN rail at either side...