Banner ABR 7000 Series Quick Start Manual Download Page 7

Specifications

Supply Voltage

10 V dc to 30 V dc

Consumption

0.7 A to 0.2 A maximum

Communication Interface

Main RS232 or RS422 full duplex: 2400 bit/s to 115200 bit/s

Auxiliary - RS232: 2400 to 115200 bit/s

Ethernet8: 10/100 Mbit/s

Inputs

Input 1 (External Trigger) and Input 2 opto-isolated and polarity insensitive

Outputs

3 NPN or PNP short circuit protected outputs available

Optical Features

See the Instruction Manual for details

LED Safety: LED emission according to EN 62471

Imager

1.3 MP: 1280 × 1024 pixels, SXGA

Construction

Aluminum

Operating Conditions

Operating Temperature9: 0 °C to +50 °C (+32 °F to +122 °F)

Liquid lens models Operating Temperature9: 0 °C to +45 °C (+32 °F to +113 °F)

Storage Temperature: –20 °C to +70 °C (–4 °F to +158 °F)

90% maximum relative humidity (non-condensing)

Environmental Rating

IEC IP6710

Parameter Storage

Permanent memory (Flash)

Other

Smart Teach Button (configurable via Barcode Manager), Beeper

Required Overcurrent Protection

WARNING: Electrical connections must be made by

qualified personnel in accordance with local and na-

tional electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per

the supplied table.

Overcurrent protection may be provided with external fusing or via Current Limit-

ing, Class 2 Power Supply.

Supply wiring leads < 24 AWG shall not be spliced.

For additional product support, go to 

www.bannerengineering.com

.

Supply Wiring (AWG)

Required Overcurrent Protection (Amps)

20

5.0

22

3.0

24

2.0

26

1.0

28

0.8

30

0.5

Certifications

Barcode Types

1-D and stacked

2-D

POSTAL

PDF417 Standard and Mi-

cro PDF417

Code 128 (GS1-128)

Code 39 (Standard and Full

ASCII)

Code 32

MSI

Standard 2 of 5

Matrix 2 of 5

Interleaved 2 of 5

Codabar

Code 93

Pharmacode

EAN-8/13-UPC-A/E (includ-

ing Addon 2 and Addon 5)

GS1 DataBar Family

Composite Symbologies

Data Matrix ECC 200

(Standard, GS1 and Direct

Marking)

QR Code

(Standard and Direct Mark-

ing)

Micro QR Code

MAXICODE

Aztec Code

Australia Post

Royal Mail 4 State Custom-

er

Kix Code

Japan Post

PLANET

POSTNET

POSTNET (+BB)

Intelligent Mail

Swedish Post

FCC Statement

Modifications or changes to this equipment without the expressed written approval of Banner Engineering could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this

device must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre-

quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in

a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

PC Requirements—

Barcode Manager

Administrative rights are required to install the Barcode Manager software.

Operating System

Microsoft

®

 Windows

®

 operating system version XP SP3, 7, 8, or 1011

Barcode Manager does not currently support Windows Embedded (often used in

industrial PCs and/or PLCs)

System Type

32-bit or 64-bit

Hard Drive Space

2 GB hard disk for 64-bit machines; 1 GB hard disk for 32-bit machines

Memory (RAM)

1 GB RAM

Processor

2.00 GHz or faster microprocessor

Screen Resolution

One 19-inch or larger monitor, optimized for 1280×1024 resolution

Third-Party Software

Web Browser: Google Chrome, Mozilla Firefox, Microsoft Internet Explorer, Opera,

etc.

Connection

100 Base-T Ethernet

8

The Ethernet interface supports application protocols: TCP/IP, EtherNet/IP, Modbus TCP

9

High ambient temperature applications should use metal mounting bracket for heat dissipation.

10

IEC IP67 when correctly connected to IP67 cables with seals.

11

Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries.

ABR 7000

 

 

P/N 207633 Rev. A

www.bannerengineering.com - Tel: +1-763-544-3164

7

Summary of Contents for ABR 7000 Series

Page 1: ...7112 RSE2 12 mm manual focus Red ABR7116 RSE2 16 mm manual focus Red ABR7106 RSE2 6 mm manual focus Red ABR7106 MSE2 6 mm manual focus Multicolored DPM ABR71L9 RSE2 9 mm autofocus Red ABR71L9 MSE2 9 m...

Page 2: ...causing eye injury within the duration of a blink aversion response of 0 25 seconds They also must emit only visible wavelengths 400 to 700 nm Therefore an ocular hazard may exist only if individuals...

Page 3: ...ant earth ground by means of a flat copper braid shorter than 100 mm Conect pin Earth of the TCNM ACBB1 connection box to a good earth ground For direct connections connect the cable shield to the loc...

Page 4: ...Figure 7 Smart Teach Interface Setup Mode 2 Release the button to enter Setup mode The Setup LED blinks until the procedure is completed The Setup procedure ends when the Image Acquisition parameters...

Page 5: ...search for Control Panel b In Control Panel click Network and Internet then click Network and Sharing Center and then click Change adapter settings c Right click on the connection that you want to ch...

Page 6: ...mic Self Tuning option 1D or 2D code Select Include Image Filtering to find the best decoding condition 8 Click Start The reader begins acquiring images adjusting the brightness and focus for autofocu...

Page 7: ...t Mail Swedish Post FCC Statement Modifications or changes to this equipment without the expressed written approval of Banner Engineering could void the authority to use the equipment This device comp...

Page 8: ...is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA...

Reviews: