background image

P/N 118000 rev. A

   

9

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

Tool Options

NOTE: Tool availability depends on P4 model.

creating

inspections

creating

inspections

This screen automatically configures the parameters chosen 

in the Tools screen.

a.   

Choose the sample size

b.   

Click 

Start

c.   

Trigger the controller with the external trigger device

d.   

Click 

Stop

e.   

Click 

Next

 to proceed to 

Run

Before entering 

Run

, save the inspection file to one of the  

12 memory locations on the Sensor.

3.

TIPS 

•  Each inspection 

must contain at 

least one Vision 

tool and one 

Test tool.

•  Save a backup 

copy of your 

inspection to 

the host PC.

Tool Name

Function

Description

Location 

Tools

GEO Find

Translation and rotation 

Locates the target by searching for a taught 

pattern and compensates for translation and 

rotation.

Locate

Translation and rotation 

Finds the edge of the part and compensates for 

translation and rotation (if selected).

Vision

 T

ools

GEO Count

Finds one or more patterns

Locates and counts a taught pattern.

Edge

Counts and locates edges

Detects and counts transitions between bright 

and dark pixels. The total number of edges can 

be counted, and the position of each edge can 

be found.

Object

Locates and counts objects, 

determines midpoints, and 

measures widths

Detects the edges of dark and bright objects, 

locates their midpoints, counts dark and bright 

objects, and measures the width of each dark 

and bright object.

Analysis 

Tools

Measure

Measures between points

Measures distance between two prescribed 

points. These points can be either edges or 

centroid locations.

Test

Logic 

input/output

Evaluates results of selected Vision and 

Analysis tools to determine whether an 

inspection passes or fails. It also performs 

logical operations and activates outputs.

Summary of Contents for PresencePlus P4 EDGE

Page 1: ...Printed in USA 12 04 P N 118000 rev A Models included GEO EDGE...

Page 2: ...t circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energized or de energized sensor output condition Consult your current Banne...

Page 3: ...is not required for running inspections after the inspection files have been stored in the Sensor s memory Start Hook Up the Hardware Install the Software and Establish Communications Acquire an Imag...

Page 4: ...le to the NTSC Video monitor connector 3 Connect the Ethernet cable from your PC to the Sensor at the RJ 45 connector a If connecting directly from the PC use a crossover cable b If connecting the Sen...

Page 5: ...ete I O 3 In Out 8 Light Blue Discrete I O 4 In Out 9 Violet RS 232 RX Input 10 Green RS 232 Signal Ground Output 11 Blue Common Signal Ground Input 12 Brown 10 30V dc Input TIPS The trigger device ca...

Page 6: ...CD b Click Install PresencePLUS Software a Right mouse click on Network Neighborhood and select Properties b Open the TCP IP Properties under the Protocols tab c Change the IP address to 192 168 0 2...

Page 7: ...back cover for part number for detailed instructions on serial port configuration 3 If using an optional NTSC video monitor verify that the monitor is displaying an image 4 When the software launches...

Page 8: ...part c Add Measure tool s to create distance measurements from points found d Add Test tool s to set the Pass Fail criteria The Vision and Measure tools are inputs to the Test tool NOTES Click Quick T...

Page 9: ...ompensates for translation and rotation Locate Translation and rotation Finds the edge of the part and compensates for translation and rotation if selected Vision Tools GEO Count Finds one or more pat...

Page 10: ...via Product Change and Product Select lines TIPS When using the Hardware input pulse the Product Change and Product Select inputs to initiate an inspection change See User s Manual for complete inform...

Page 11: ...7 System Setup Use the System Setup screen to change discrete I O the communication port the product change the strobe output for external lighting control the trigger input and to view diagnostic inf...

Page 12: ...of neutral detergent Avoid getting dirt on the Sensor s imager the area behind the lens If the imager is dirty use anti static compressed air to blow off the dust Cleaning the Sensor Lens Regularly re...

Page 13: ...e try again Image is frozen on PC and monitor Sensor Power Error LED is Red Software restart needed or loose connections Restart the PresencePLUS software If the connections are secure call a Banner A...

Page 14: ...29 kg 0 642 lb Environmental Rating IEC IP20 NEMA 1 Operating Temperature 0 C to 50 C 32 F to 122 F Maximum Relative Humidity 90 non condensing Display Options PC or NTSC video 9 m 30 max cable lengt...

Page 15: ...tage 10 30V dc Current 500 mA max Acquisition 500 frames per second max Image size 126 x 98 pixels Levels of Gray Scale 256 Imager 2 56 x 2 06 mm 3 25 mm diagonal CMOS Pixel Size 20 x 20 microns Expos...

Page 16: ...ering com Email sensors bannerengineering com P N 118000 rev A Models Tools PresencePLUS P4 Models User s Manual Part Number Tools Locate GEO Find GEO Count Edge Object Measure Test Comm GEO 117020 X...

Reviews: