background image

P/N 118000 rev. A

   

7

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

sensor

startup

sensor

startup

step 5

step 5

Launching Software

1.  

Start the PresencePLUS program by clicking

 

Start

 > 

Program Files

 > 

PresencePLUS

.

2. 

At start-up, PresencePLUS P4 will try to communicate with the Sensor.

      •   If communication with the Sensor is successful, the application will launch 

and display the Setup or Run screen.

      •   If the current communication port is not available, the application 

will prompt you to select a different port. Click 

OK

 to access the 

Communications window.

 

To Change the Communication Port

    •   Ethernet connection:

       a. 

Choose 

Ethernet [RJ45]

      b.   

Type: 

192.168.0.1

 in the

space provided

     

c. 

Click 

OK

    •   Serial connection:
       Choose 

serial

. Refer to the User’s Manual (on software CD; see back cover 

for part number) for detailed instructions on serial port configuration.

3.  

If using an optional NTSC video monitor, verify that the monitor is displaying an 

image.

4.  

When the software launches, create an inspection, configure the discrete I/O,

and begin running inspections. 

NOTE:   Initially, all discrete I/O are configured as inputs. Go to the System window 

to change the discrete I/O. For detailed configuration information, refer to 

the User’s Manual (on software CD; see back cover for part number).

TIPS

DO NOT click

 

Modify Camera 

IP Address

when trying to

establish

communications. 

Modify

 works 

only after 

communications 

have been 

established.

step 4

step 4

Starting the PresencePLUS P4

1.  

Power up the hardware and verify 

that the Power/Error light turns 

Green.

Green = Ready

Yellow = Trigger

Green = Ready

Yellow = Trigger

Green = Power

Red = Error

Green = Power

Red = Error

Green = Pass

Red = Fail

In-Line Sensor

Right-Angle

Sensor

Green = Pass

Red = Fail

Summary of Contents for PresencePlus P4 EDGE

Page 1: ...Printed in USA 12 04 P N 118000 rev A Models included GEO EDGE...

Page 2: ...t circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energized or de energized sensor output condition Consult your current Banne...

Page 3: ...is not required for running inspections after the inspection files have been stored in the Sensor s memory Start Hook Up the Hardware Install the Software and Establish Communications Acquire an Imag...

Page 4: ...le to the NTSC Video monitor connector 3 Connect the Ethernet cable from your PC to the Sensor at the RJ 45 connector a If connecting directly from the PC use a crossover cable b If connecting the Sen...

Page 5: ...ete I O 3 In Out 8 Light Blue Discrete I O 4 In Out 9 Violet RS 232 RX Input 10 Green RS 232 Signal Ground Output 11 Blue Common Signal Ground Input 12 Brown 10 30V dc Input TIPS The trigger device ca...

Page 6: ...CD b Click Install PresencePLUS Software a Right mouse click on Network Neighborhood and select Properties b Open the TCP IP Properties under the Protocols tab c Change the IP address to 192 168 0 2...

Page 7: ...back cover for part number for detailed instructions on serial port configuration 3 If using an optional NTSC video monitor verify that the monitor is displaying an image 4 When the software launches...

Page 8: ...part c Add Measure tool s to create distance measurements from points found d Add Test tool s to set the Pass Fail criteria The Vision and Measure tools are inputs to the Test tool NOTES Click Quick T...

Page 9: ...ompensates for translation and rotation Locate Translation and rotation Finds the edge of the part and compensates for translation and rotation if selected Vision Tools GEO Count Finds one or more pat...

Page 10: ...via Product Change and Product Select lines TIPS When using the Hardware input pulse the Product Change and Product Select inputs to initiate an inspection change See User s Manual for complete inform...

Page 11: ...7 System Setup Use the System Setup screen to change discrete I O the communication port the product change the strobe output for external lighting control the trigger input and to view diagnostic inf...

Page 12: ...of neutral detergent Avoid getting dirt on the Sensor s imager the area behind the lens If the imager is dirty use anti static compressed air to blow off the dust Cleaning the Sensor Lens Regularly re...

Page 13: ...e try again Image is frozen on PC and monitor Sensor Power Error LED is Red Software restart needed or loose connections Restart the PresencePLUS software If the connections are secure call a Banner A...

Page 14: ...29 kg 0 642 lb Environmental Rating IEC IP20 NEMA 1 Operating Temperature 0 C to 50 C 32 F to 122 F Maximum Relative Humidity 90 non condensing Display Options PC or NTSC video 9 m 30 max cable lengt...

Page 15: ...tage 10 30V dc Current 500 mA max Acquisition 500 frames per second max Image size 126 x 98 pixels Levels of Gray Scale 256 Imager 2 56 x 2 06 mm 3 25 mm diagonal CMOS Pixel Size 20 x 20 microns Expos...

Page 16: ...ering com Email sensors bannerengineering com P N 118000 rev A Models Tools PresencePLUS P4 Models User s Manual Part Number Tools Locate GEO Find GEO Count Edge Object Measure Test Comm GEO 117020 X...

Reviews: