7.3.3 Stationary Regen
Warnings
7.3.4 Manual Stationary
DPF Regeneration
To initiate and see the status
parameters during DPF regeneration.
1.
Select “
Diagnostics
” from the
main “
MENU
”.
2.
Select “
Vehicle
” for vehicle
diagnostics.
3.
Select “
Stationary Regen
” to
begin manual stationary regeneration
process.
In order to have selected
“
Stationary Regen
” the previous
list of conditions in
"7.3.2 Error
List/Conditions for Manual
Regeneration" on page 36
must
have been met otherwise error alert
would have prevented it from being
selected.
4.
Before proceeding with manual
regeneration you will have to read and
follow several caution messages by
pressing the right arrow button. This
will lead you to Gale Banks Engineering
liability disclaimer message. Must
press the down arrow
(see
Figure 7-5, A
) to agree and
continue manual regeneration.
5.
After pressing down to agree to
the disclaimer select “
Yes
” to proceed
with manual regen. (See
Figure
7-5, B
) This will initiate and display
DIAGNOSTICS,
CONTINUED
Performing a stationary Regen
will result in tailpipe exhaust gas
temperatures greater than 600 F. It
is important to follow to following
safety procedure to ensure a safe
stationary Regen.
1.
Park vehicle outdoors and
keep people, other vehicle, and
combustible materials away from the
exhaust tailpipe
2.
Do not leave vehicle unattended
3.
Do not connect any shop hoses to
the exhaust.
4.
Open the hood and keep vehicle
in an open environment to allow
proper ventilation
5.
Check that coolant and oil levels
are at proper levels before and after
Regen
WARNING!
*Liability Disclaimer*
Gale Banks Engineering shall in
no way be responsible for the
products proper use and service.
THE USER WAIVES ALL LIABILITY
CLAIMS.
Figure 7-5
A
B
Summary of Contents for 61410