background image

 

L 900 Series Oven Range (AGA No. 4921-07)

 

 

April 2011

 

 

BEFORE CONNECTING NEW PIPE TO THIS APPLIANCE, THE PIPE MUST BE BLOWN OUT THOROUGHLY  TO 
REMOVE ALL FOREIGN MATERIAL.  FOREIGN MATERIAL IN THE BURNER AND GAS CONTROLS WILL CAUSE 
IMPROPER AND DANGEROUS OPERATION. 
  
Connect to gas. 

 
P

RESSURE TEST POINT

 

All appliances that are dispatched from our factory are tested and adjusted according to the specifications for 
the required gas type.  The regulator may require adjustment to achieve required gas pressure. 
 
Check the burner pressure at the test point on the regulator. The test point pressure should be adjusted to 
1.00 kPa – Natural gas or 2.55 kPa – Propane gas with the burners operating at maximum. 

 
B

EFORE 

L

EAVING 

-

 

C

OMMISSIONING

 

Check 

all

 connections for gas leaks with soap and water. 

Do not

 use a naked flame for detecting leaks.   

 
Ignite the pilot and main burners as prescribed below to ensure correct operation of gas valves, burners and 
ignition.  When satisfied with the operation of the appliance, please instruct the user on the correct method of 
operation.  Ensure that this instruction manual is left with owner of the appliance. 

 

C

OMMISSIONING 

(B

OILING 

T

OP 

S

ECTION

)

 

If appliance fitted with pilot and/or flame failure 

A.

 

Ensure gas control is in the „OFF‟ position. 

B.

 

Depress operating knob of relevant burner and turn anti-clockwise to „PILOT‟ position and light pilot. 

C.

 

Observe the pilot light is established. Pilot flame should be between 10-20mm in size and be in direct 
contact with thermocouple (where fitted). Should the thermocouple require adjustment, lift off trivet 
and  undo  the  nut  holding  thermocouple  on  pilot  assembly.    After  adjusting  reassemble  in  reverse 
order. 

D.

 

If pilot light does not light, turn control knob to „OFF‟ position, wait five minutes and repeat steps 

to 

C

.  

Note. 

If pilot flame is smaller than the parameters described in part 

A

, check the pilot gas line 

(6mm stainless steel flexible tube) for any possible blockages/crimpage.  To gain access to gas control 
components, remove control knobs and undo screws located on either side and at the top of the front 
panel. Remove front panel (reassemble in reverse order). 

E.

 

Once pilot is established turn control knob anti-clockwise to the „HIGH‟ position. Examine flame. 

F.

 

Turn control knob clockwise to the „LOW‟ position.  Examine flame. Should flame extinguish when on 
the  low  position,  adjust  flame  adjustment  screw  on  gas  cock.  To  gain  access  to  gas  cock,  gently 
remove  gas  cock  knobs  from  front  of  appliance  and  remove  screws  holding  front  panel  in  position. 
Screw  flame  adjustment  screw  anti-clockwise  for  greater  flame  on  lower  setting,  clockwise  for  less 
flame on low setting. REASSEMBLE IN REVERSE ORDER. 

G.

 

Turn control knob clockwise to the „OFF‟ position. 

H.

 

Repeat steps 

to 

H

 for all burners. 

 
If appliance is not fitted with pilot and/or flame failure. 

A.

 

Ensure gas control is in the „OFF‟ position. 

B.

 

Depress operating knob of relevant burner and turn anti-clockwise 180

o

 to the „LOW‟ position and light 

burner. Examine flame.  Should  flame extinguish when on the low position, adjust flame adjustment 
screw on gas cock. To gain access to gas cock, gently remove gas cock knobs from front of appliance 
and remove screws holding front panel in position. Screw flame adjustment screw anti-clockwise for 
greater  flame  on  lower  setting,  clockwise  for  less  flame  on  low  setting.  REASSEMBLE  IN  REVERSE 
ORDER. 

Summary of Contents for L 900-4

Page 1: ...No s L 900 4 L 900 5 L 900 6 AGA Approval No 4921 B S Commercial Kitchen Appliances Pty Ltd 57 Plateau Road Reservoir VIC 3073 AUSTRALIA Tel 61 3 9469 4754 Fax 61 3 94694504 Web www b scka com au Ple...

Page 2: ...g Commissioning 8 Commissioning Boiling Top Section 8 Commissioning Oven Section 9 Operating Instructions 10 Figure 1 Oven Range Knowing your appliance 10 Figure 2 Control Panel Boiling Top Section 11...

Page 3: ...Replacing Servicing Oven Thermocouple Lead 14 Replacing Servicing Oven Pilot Burner 15 Aeration of Oven Burner 15 Gas Conversion 15 TABLE 3 Spare Parts List 16...

Page 4: ...umber 4921 GasType s Natural Gas PropaneGas NOTE L900 4 isonlyapprovedforNaturalGas We are confident that you will be delighted with your B S appliance and that it will become the backbone of your kit...

Page 5: ...ACINITY OF THIS APPLIANCE NEVER SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION ENSURE ANY TRANSIENT PROTECTION IS REMOVED BEFORE INSTALLING THE APPLIANCE ENSURING ANY POSSIB...

Page 6: ...900 6 Width mm 600 600 Depth mm 840 840 Height mm 1 100 1 100 Working height mm 900 900 FIGURE 1 PLUMBING CONNECTIONS TABLE 3 PLUMBING CONNECTIONS Connection Position from Floor mm Position from Front...

Page 7: ...impervious to fat grease and vapour The hood must be made so it can be readily and effectively cleaned The hood must be made with its inside surfaces free of obstructions and all joints grease tight T...

Page 8: ...the nut holding thermocouple on pilot assembly After adjusting reassemble in reverse order D If pilot light does not light turn control knob to OFF position wait five minutes and repeat steps A to C...

Page 9: ...reassemble in reverse order Note If pilot flame is smaller than the parameters described in part C check the pilot gas line 6mm stainless steel flexible tube for any possible blockages crimpage D If...

Page 10: ...e floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phone in your building Call the local gas supplier immediately and foll...

Page 11: ...to the OFF position Wait for five minutes before attempting to re light repeat steps 1 4 5 Once pilot is lit push down and slowly turn the knob anti clockwise to the HIGH position 6 Adjust the size of...

Page 12: ...he use of steel wool abrasive cloths cleansers powders should not be used to clean this appliance DAILY CHECKS SERVICE Look for any foreign materials in burner area leaks damaged knobs and any other s...

Page 13: ...ed service agent SERVICING INSTRUCTIONS WARNING Servicing shall be carried out by authorised personnel only Failure to do so will void the B S warranty and may result in damage to equipment or injury...

Page 14: ...uple to gascock located at the rear of the gascock b Gently remove gascock from spigot c REASSEMBLE IN REVERSE ORDER 6 The pilot light located on the RHS of the burner can be removed from the gascock...

Page 15: ...regulator ensuring flow arrow on regulator is pointing the correct way 2 Boiling Top Burners with without flame failure a Remove trivets b Remove front burners by lifting the burner at the rear and th...

Page 16: ...me failure device 800 750mm Sleeved Thermocouple Front row burner boiling top section flame failure device 668 1 200mm Sleeved Thermocouple Flame failure device Oven Section 123 Oven Control Minisit T...

Page 17: ...is hitting thermocouple Contact manufacturer or authorised service agent Contact manufacturer or authorised service agent Pilot established main burner not lighting Faulty thermocouple Faulty flame f...

Page 18: ...L 900 Series Oven Range AGA No 4921 07 April 2011 18...