L 900 Series Oven Range (AGA No. 4921-07)
April 2011
15
3.
Release the thermocouple head from the pilot assembly inside the oven.
4.
Pull out the thermocouple lead from the top.
5.
REASSEMBLE IN REVERSE ORDER.
R
EPLACING
/S
ERVICING
O
VEN
P
ILOT
B
URNER
To replace the pilot burner:
1.
Undo the union connecting the pilot feed tube to the RHS of the gas control.
2.
Undo the screw holding the pilot assembly to the inlet of the oven burner.
3.
The pilot assembly can then be lifted out.
4.
REASSEMBLE IN REVERSE ORDER
A
ERATION OF
O
VEN
B
URNER
For adjustment of aeration to oven burner:
1.
Lift off the RHS deflector plate.
2.
Loosen the butterfly valve adjustment screw.
3.
Adjust the butterfly valve at the inlet to the burner while it is in operation.
4.
When the burner is operating correctly re tighten the adjustment screw.
5.
REASSEMBLE IN REVERSE ORDER
G
AS
C
ONVERSION
Prior to commencing any conversions from Natural to Propane Gas, or Propane to Natural gas, please ensure
that the gas supply is correct for the appliance being converted and that adequate supply pressure and
volume is available.
Prior to performaing any conversions, please ensure gas supply to appliance (if
already installed) is turned off (isolated).
1.
Regulator
a.
Remove existing regulator located at the bottom right hand side of the appliance.
b.
Install replacement regulator ensuring flow arrow on regulator is pointing the correct way.
2.
Boiling Top Burners (with/without flame failure)
a.
Remove trivets
b.
Remove front burners by lifting the burner at the rear, and then slowly pulling it towards the
splash back (rear) of the appliance off the injector.
c.
Remove rear burners by lifting the burner at the rear, and then slowly pulling it towards the
splash back (rear) of the appliance off the injector.
d.
Unscrew burner injector located on the manifold from the base and replace with correctly
sized injector. Refer TABLE 1: Nominal Terminal Input Rates & Injector Sizes (page 3 of this
booklet).
e.
If the boiling section is fitted with flame failure device, remove pilot as prescribed under
R
EPLACING
/S
ERVICING
B
OILING
T
OP
G
AS
C
OCKS
,
T
HERMOCOUPLES AND
P
ILOT
and replace pilot injector
spud with correctly sized pilot injector spud. Refer TABLE 1: Nominal Terminal Input Rates &
Injector Sizes (page 3 of this booklet).
f.
REASSEMBLE IN REVERSE ORDER
3.
Oven Burner (with flame failure)
a.
Remove wire trays from oven compartment
b.
Remove all three baffle panels concealing the burner.
c.
Undo burner mounting screw located on the left hand side of the burner.
d.
Gently lift burner up and then slowly pull off the oven burner injector.
a.
Unscrew oven burner injector and replace with correctly sized injector. Refer TABLE 1:
Nominal Terminal Input Rates & Injector Sizes (page 3 of this booklet).
b.
To change oven pilot injector spud, undo the union connecting the pilot feed tube to the RHS
of the gas control.