L 900 Series Oven Range (AGA No. 4921-07)
April 2011
16
c.
Undo the screw holding the pilot assembly to the inlet of the oven burner.
d.
The pilot assembly can then be lifted out.
e.
Change pilot injector spud with correctly sized injector Refer TABLE 1: Nominal Terminal Input
Rates & Injector Sizes (page 3 of this booklet).
e.
REASSEMBLE IN REVERSE ORDER.
Once conversion is complete, please refer to installation instructions of this booklet paying
particular attention T
EST
P
OINT
P
RESSURE
and C
OMMISSIONING
-
B
EFORE
L
EAVING
.
TABLE
3:
S
PARE
P
ARTS
L
IST
Part
Number
Description
122A
Short Arm Burner (Front row burner boiling top section) Natural & Propane Gas
122B
Long Arm Burner (Back row burner boiling top section) Natural & Propane Gas
125LNG
Oven Burner (Natural Gas)
125LLP
Oven Burner (Propane Gas)
127
Boiling Top Section Trivet (300 x 300mm)
128
Boiling Top Section Trivet (300 x 450mm)
120ANG
Boiling Top Burner Injector (Natural Gas)
120ALP
Boiling Top Burner Injector (Propane Gas)
123ANG
Oven Burner Injector (Natural Gas)
123ALP
Oven Burner Injector (Propane Gas)
034NG
Delta Pilot (Natural Gas)
034LPG
Delta Pilot (Propane Gas)
124
450mm Sleeved Thermocouple (Front row burner boiling top section – flame failure device)
800
750mm Sleeved Thermocouple (Front row burner boiling top section – flame failure device)
668
1,200mm Sleeved Thermocouple (Flame failure device – Oven Section)
123
Oven Control – Minisit Thermostat
034ANG
Delta Pilot Injector Spud (Natural Gas)
034ALP
Delta Pilot Injector Spud (Propane Gas)
665NG
¾” Oara Regulator (Natural Gas)
665LP
¾” Oara Regulator (Propane Gas)
129
Gas Cock Control – With flame failure device
129A
Gas Cock Control – With no flame failure device
036
Piezo Ignition
666
Piezo ignition Lead
651
Flexi-Gas Tube from Gas Cock to Flame Failure Device (Front row burner boiling top section)
652
Flexi-Gas Tube from Gas Cock to Flame Failure Device (Back row burner boiling top section)
653
Flexi-Gas Tube from Gas Control to Flame Failure Device (Oven burner section)
667
Flexi-Gas Tube from Gas Control to Oven Burner (Oven burner section)
657
Oven Racks
337A
Black Control Knob for Boiling Top Gas Cock (No Pilot-Flame Failure Device)
337B
Black Control Knob for Boiling Top Gas Cock (Pilot-Flame Failure Device)
658
Oven Rack Guide Rails
TABLE
5:
T
ROUBLESHOOTING
FAULT
POSSIBLE CAUSE
CHECKS
Pilot light not igniting
Blockage of pilot
Adjustment of pressure from flame failure
control
Check pilot injector is not blocked as
described in servicing instructions – pilot
and flame safeguard
Check gas pressure to pilot as described
under servicing instructions – adjustments