L 900 Series Oven Range (AGA No. 4921-07)
April 2011
5
IMPORTANT
WARNINGS
THIS APPLIANCE SHALL ONLY BE INSTALLED/SERVICED BY AN
AUTHORISED INSTALLER.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH
THE SPECIFIED INSTRUCTIONS AND SPECIFICATIONS.
IMPROPER INSTALLATION OR OPERATION OF THIS APPLIANCE
MAY RESULT IN PRODUCT FAILURE WHICH MAY LEAD TO
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
CAUTION MUST BE TAKEN WHEN OPERATING THIS APPLIANCE
TO MINIMISE RISK OF FIRE. THE APPLIANCE
MUST NOT
BE
LEFT ON UNATTENDED.
REGULAR INSPECTIONS BY AN AUTHORISED SERVICE PERSON ARE STRONGLY RECOMMENDED TO
ENSURE PROPER AND SAFE FUNCTIONING OF THIS APPLIANCE.
AFTER ANY SERVICING OR ADJUSTING OF GAS CONNECTED COMPONENTRY, GAS LEAK TEST MUST
BE CARRIED OUT TO ENSURE THERE ARE NO GAS LEAKING HAZARDS.
NEVER STORE ANY FLAMMABLE LIQUIDS/VAPOURS IN THE VACINITY OF THIS APPLIANCE. NEVER
SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
ENSURE ANY TRANSIENT PROTECTION IS REMOVED BEFORE INSTALLING THE APPLIANCE
ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS/PARTS THAT MAY HAVE
BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER.
THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT.
ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION.
F
AILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE
B&S
W
ARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL
TABLE
1:
N
OMINAL
T
ERMINAL
I
NPUT
R
ATES
&
I
NJECTOR
S
IZES
Section
Burner Injector
Size (Pilot Spud)
mm
MJ/h rating per
burner
Test Point Pressure
L 900 – 6
Natural Gas
Boiling Top Section
Oven Section
2.45 (0.35)
2.75 (0.35)
30.0
34.0
1.00 kPa
1.00 kPa
Propane Gas
Boiling Top Section
Oven Section
1.45 (0.20)
1.70 (0.20)
30.0
34.0
2.55 kPa
2.55 kPa
L 900-4
Natural Gas
Boiling Top Section
Inner Ring
Outer Ring
1.6 (0.35)
2.45
11.6
24.0
1.00 kPa
1.00 kPa