background image

 Table of contents

SDL3 Converter User's manual V 2.00 Translation of the original documentation

3

Commissioning........................................................................................................30

6.1 Basic information...........................................................................................................................................30

6.2 Switching on the device for the first time..................................................................................................... 30

6.2.1 General information before switching on the device...............................................................................30

6.2.2 Switching on the SDL3 Converter...........................................................................................................30

Software................................................................................................................... 31

7.1 Upgrade information......................................................................................................................................31

7.1.1 Firmware upgrade................................................................................................................................... 31

Maintenance.............................................................................................................32

8.1 Repairs/Complaints and replacement parts..................................................................................................32

International and national certifications...............................................................33

9.1 Directives and declarations...........................................................................................................................33

9.1.1 CE marking..............................................................................................................................................33

9.1.2 EMC Directive..........................................................................................................................................33

9.2 Certifications..................................................................................................................................................34

9.2.1 UL certification.........................................................................................................................................34

9.2.2 EAC..........................................................................................................................................................34

10 Accessories........................................................................................................... 35

10.1 General accessories................................................................................................................................... 35

10.1.1 Accessories - Order data...................................................................................................................... 35

10.2 0TB103.9x................................................................................................................................................... 36

10.2.1 General information............................................................................................................................... 36

10.2.2 Order data............................................................................................................................................. 36

10.2.3 Technical data....................................................................................................................................... 36

10.3 Cables......................................................................................................................................................... 37

10.3.1 SDL3/SDL4 cables................................................................................................................................ 37

10.3.1.1 5CASD3.xxxx-00.............................................................................................................................. 37

10.3.2 SDL cables............................................................................................................................................ 40

10.3.2.1 5CASDL.0xxx-00..............................................................................................................................40

10.3.3 SDL cables with 45° connector.............................................................................................................43

10.3.3.1 5CASDL.0xxx-01..............................................................................................................................43

10.3.4 SDL flex cables..................................................................................................................................... 46

10.3.4.1 5CASDL.0xxx-03..............................................................................................................................46

10.3.5 DVI cables............................................................................................................................................. 50

10.3.5.1 5CADVI.0xxx-00...............................................................................................................................50

10.3.6 USB cables............................................................................................................................................53

10.3.6.1 5CAUSB.00xx-00............................................................................................................................. 53

10.4 Cable strain relief clip................................................................................................................................. 55

10.4.1 5ACCRHMI.0011-000............................................................................................................................ 55

10.4.1.1 General information..........................................................................................................................55

10.4.1.2 Order data........................................................................................................................................55

10.4.1.3 Technical data..................................................................................................................................55

11 Environmentally friendly disposal.......................................................................56

11.1 Separation of materials............................................................................................................................... 56

Summary of Contents for MASDL3CON-ENG

Page 1: ...dustrial Automation GmbH is not liable for technical or editorial errors and defects in this manual In addition B R Industrial Automation GmbH assumes no liability for damages that are directly or ind...

Page 2: ...Converter for Automation PCs 8 3 3 Connection options 9 3 3 1 SDL3 operation 9 3 3 1 1 SDL3 operation with SDL3 Converter via SDL 9 3 3 1 2 SDL3 operation with SDL3 Converter via DVI 11 3 3 2 General...

Page 3: ...ons 34 9 2 1 UL certification 34 9 2 2 EAC 34 10 Accessories 35 10 1 General accessories 35 10 1 1 Accessories Order data 35 10 2 0TB103 9x 36 10 2 1 General information 36 10 2 2 Order data 36 10 2 3...

Page 4: ...required for end customers must be incorporated into the operating instructions for end customers in the respective national lan guage by the machine manufacturer or system provider 1 2 1 Organizatio...

Page 5: ...per ESD handling Electrical assemblies with housing Do not touch the connector contacts of connected cables Do not touch the contact tips on circuit boards Electrical assemblies without housing The fo...

Page 6: ...relevant regulations e g wire cross sec tion fuse protection protective ground connection 2 6 Operation 2 6 1 Protection against contact with electrical parts In order to operate programmable logic co...

Page 7: ...s and security solutions are suitable for this purpose Segmentation of the network e g separation of the IT and OT networks Firewalls for the secure connection of network segments Implementation of a...

Page 8: ...in dimension diagrams and associated tables are in millimeters mm 3 2 SDL3 Converter for Automation PCs Smart Display Link 3 offers even more advantages when used together with an external converter...

Page 9: ...s LEDs and service diagnostic data is transferred If the B R industrial PC is equipped with an SDL3 transmitter then an additional SDL3 graphics line can also be implemented The brightness of the disp...

Page 10: ...ustrial PC and SDL3 Converter is 10 m USB 1 1 is fully integrated in the SDL transfer and transferred over this distance Automation Panel with SDL3 receiver B R industrial PC SDL cable SDL3 cable SDL3...

Page 11: ...n Panels with an SDL3 receiver SDL3 interface USB1 USB2 USB 2 0 Power supply Grounding Maximum cable length for SDL3 100 m Maximum cable length for DVI and USB 5 m Requirements Automation Panel with S...

Page 12: ...0 5CASDL 0018 00 5CASDL 0050 00 5CASDL 0060 00 5CASDL 0100 00 SDL cables with 45 connector 5CASDL 0018 01 5CASDL 0050 01 5CASDL 0100 01 SDL flex cables 5CASDL 0018 03 5CASDL 0050 03 5CASDL 0100 03 DVI...

Page 13: ...CASD3 0050 00 SDL3 SDL4 cable 5 m 5CASD3 0100 00 SDL3 SDL4 cable 10 m 5CASD3 0150 00 SDL3 SDL4 cable 15 m 5CASD3 0200 00 SDL3 SDL4 cable 20 m 5CASD3 0300 00 SDL3 SDL4 cable 30 m 5CASD3 0500 00 SDL3 SD...

Page 14: ...60529 IP20 Ambient conditions Temperature Operation 0 to 55 C 2 Storage 20 to 60 C Transport 20 to 60 C Relative humidity Operation 5 to 90 non condensing Storage 5 to 95 non condensing Transport 5 t...

Page 15: ...documentation 15 3 5 1 4 Dimensions Information All specifications in dimension diagrams and associated tables are in millimeters mm 2D and 3D diagrams DXF and STEP formats can be downloaded from the...

Page 16: ...upply on page 16 2 USB In interface on page 19 5 Grounding on page 17 3 LED status indicators on page 19 6 SDL3 Out interface on page 19 3 5 2 1 1 24 VDC power supply Danger The device is only permitt...

Page 17: ...1 1 Grounding Caution The functional ground power supply pin 2 and ground connection must be connected to the central grounding point e g control cabinet or system via the shortest possible path with...

Page 18: ...DL transfer The following table shows the relationship between segment length and maximum resolution depending on the SDL cable Resolution SDL cable Segment length m VGA 640 x 480 SVGA 800 x 600 XGA 1...

Page 19: ...On 50 brightness Active SDL communication Faulty or incomplete firmware up grade TBD from what Link PC Con verter Blinking No active SDL communication Status Yellow Blinking On 50 brightness Off No ac...

Page 20: ...ector 5 m 43 5CASDL 0100 01 SDL cable 45 degree connector 10 m 43 SDL cables 5CASDL 0008 00 SDL cable 0 8 m 40 5CASDL 0018 00 SDL cable 1 8 m 40 5CASDL 0050 00 SDL cable 5 m 40 5CASDL 0060 00 SDL cabl...

Page 21: ...e following figure and table exclusively show the thermal view of the complete system If additional space is required for operating or servicing the device or using accessories e g cable strain relief...

Page 22: ...nd from the power supply All covers and components accessories hardware and cables must be installed or secured before the device is connected to the power supply and switched on Installation Informat...

Page 23: ...storage When transporting at low temperatures or in the event of large temperature fluctuations the collection of moisture in or on the device is not permitted Moisture can cause short circuits in ele...

Page 24: ...onverter The frame on the back of the device allows the system to be installed on a top hat rail TS35 that corresponds to the EN 50022 standard 35 1 7 5 Figure 3 Top hat rail 5 2 1 Procedure 1 Attach...

Page 25: ...nverter according to the following figure and secured with the supplied locating screws M3 max tightening torque 0 5 Nm The length overhang is not permitted to be removed and the cable strain relief c...

Page 26: ...el must be interrupted Before connecting the DC power cable it must be checked whether it has been disconnected from the voltage source e g power supply 5 4 1 1 Wiring The DC power cable must be imple...

Page 27: ...rference is safely diverted Connect the device to the central grounding point e g the control cabinet or the system using the shortest possible low resistance path Cable design with at least 2 5 mm pe...

Page 28: ...ecting cables When connecting or installing cables the bend radius specification must be observed For this specification see the technical data of the respective cable The maximum tightening torque of...

Page 29: ...slation of the original documentation 29 5 6 Removing the SDL3 Converter 5 6 1 Procedure 1 Pull the SDL3 Converter downwards 1 and slightly in the opposite direction away from the top hat rail 2 This...

Page 30: ...he ground connection Before installing additional hardware the device must have been started up Caution Before the device is started up it must be gradually adapted to room temperature Exposure to dir...

Page 31: ...w br automation com 7 1 1 Firmware upgrade To upgrade the firmware an APC3100 APC2200 APC2100 APC910 or PPC3100 or PPC900 with compatible MTCX firmware must be connected in addition to an Automation P...

Page 32: ...ermitted to be used for maintenance work 8 1 Repairs Complaints and replacement parts Danger Unauthorized opening or repair of a device may result in personal injury and or serious damage to property...

Page 33: ...nts of EU directive Electromagnetic compatibility 2014 30 EU and are designed for industrial applications EN 61131 2 2007 Programmable controllers Part 2 Equipment requirements and tests EN 61000 6 2...

Page 34: ...ailable on the website and in the user s manual under the technical data in section Certifications or in the associated certificates 9 2 1 UL certification Ind Cont Eq E115267 Products with this mark...

Page 35: ...observed when operating the complete system All components listed in this manual have undergone intensive system and compatibility testing and been approved accordingly B R cannot assume any functiona...

Page 36: ...o 100 Vibration A 0 7 g EMC B bridge and open deck 2 Terminal block Note Protected against vibration by the screw flange Nominal data per UL Number of pins 3 female Type of terminal block Screw clamp...

Page 37: ...ffer from those of the complete system The data specified for the complete system applies to the complete system in which this accessory is installed for example Model number 5CASD3 0030 00 5CASD3 005...

Page 38: ...operly connected Ambient conditions Temperature Storage 40 to 70 C Fixed installation 40 to 70 C Flexible installation 40 to 70 C 10 to 50 C Mechanical properties Dimensions Length 3 m 5 m 10 m 15 m 2...

Page 39: ...n wh or bl wh bl or wh br br Shield 10 3 1 1 7 Wiring The following information and figure apply if a field assembled cable is used and connected to an RJ45 network connector e g patch panel instead o...

Page 40: ...he complete system in which this accessory is installed for example Model number 5CASDL 0008 00 5CASDL 0018 00 5CASDL 0050 00 5CASDL 0060 00 5CASDL 0100 00 General information Certifications CE Yes UL...

Page 41: ...206 g Approx 300 g Approx 580 g Approx 700 g Approx 1500 g Table 10 5CASDL 0008 00 5CASDL 0018 00 5CASDL 0050 00 5CASDL 0060 00 5CASDL 0100 00 Technical data 1 Yes but applies only if all components...

Page 42: ...ble shield Pin Pinout Pin Pinout 1 TMDS data 2 negative 13 XUSB0 positive 2 TMDS data 2 positive 14 5 V 3 Shielding TMDS data 2 and SDL 15 GND 4 SDL negative 16 Hot plug detection 5 SDL positive 17 TM...

Page 43: ...this accessory is installed for example Model number 5CASDL 0018 01 5CASDL 0050 01 5CASDL 0100 01 General information Certifications CE Yes UL cULus E115267 Industrial control equipment HazLoc cULus H...

Page 44: ...01 5CASDL 0050 01 5CASDL 0100 01 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2...

Page 45: ...ble shield Pin Pinout Pin Pinout 1 TMDS data 2 negative 13 XUSB0 positive 2 TMDS data 2 positive 14 5 V 3 Shielding TMDS data 2 and SDL 15 GND 4 SDL negative 16 Hot plug detection 5 SDL positive 17 TM...

Page 46: ...umber 5CASDL 0018 03 5CASDL 0050 03 5CASDL 0100 03 General information Certifications CE Yes UL cULus E115267 Industrial control equipment HazLoc cULus HazLoc E180196 Industrial control equipment for...

Page 47: ...t ed 300000 cycles at 15x cable diameter 4800 cycles hour Drag chain data Flex cycles 300 000 Speed 4800 cycles hour Bend radius 180 mm 15x cable diameter Hub 460 mm Weight Approx 460 g Approx 1020 g...

Page 48: ...tructure 5CASDL 0xxx 03 Element Pinout Cross section TMDS data 0 26 AWG TMDS data 1 26 AWG TMDS data 2 26 AWG DVI TMDS clock 26 AWG XUSB0 26 AWG USB XUSB1 26 AWG Data SDL 26 AWG DDC clock 24 AWG DDC d...

Page 49: ...ble shield Pin Pinout Pin Pinout 1 TMDS data 2 negative 13 XUSB0 positive 2 TMDS data 2 positive 14 5 V 3 Shielding TMDS data 2 and SDL 15 GND 4 SDL negative 16 Hot plug detection 5 SDL positive 17 TM...

Page 50: ...Yes UL cULus E115267 Industrial control equipment DNV GL Temperature B 0 55 C Humidity B up to 100 Vibration A 0 7 g EMC B bridge and open deck 1 GOST R Yes Cable construction Wire cross section 28 A...

Page 51: ...n 51 10 3 5 1 4 Bend radius specification Connector Ferrite bead Ferrite bead Ferrite bead Bend radius Connector Ferrite bead Bend radius Ferrite bead Ferrite bead Figure 18 Bend radius specification...

Page 52: ...10 3 5 1 6 Cable pinout If you wish to assemble a suitable cable yourself the cable must be wired according to this pinout Information Functionality is only guaranteed for the cables available from B...

Page 53: ...ied for the complete system applies to the complete system in which this accessory is installed for example Model number 5CAUSB 0018 00 5CAUSB 0050 00 General information Certifications CE Yes UL cULu...

Page 54: ...10 3 6 1 4 Cable pinout If you wish to assemble a suitable cable yourself the cable must be wired according to this pinout Information Functionality is only guaranteed for the cables available from B...

Page 55: ...e Installing the cable strain relief clip on page 25 10 4 1 2 Order data Model number Short description Figure Accessories 5ACCRHMI 0011 000 REP strain relief USB For APC2100 APC2200 For SDL3 Con vert...

Page 56: ...possible 11 1 Separation of materials To ensure that devices can be recycled in an environmentally friendly manner it is necessary to separate out the different materials Component Disposal Programmab...

Page 57: ...Publishing information SDL3 Converter User s manual V 2 00 Translation of the original documentation 57...

Page 58: ...nverter User s manual V 2 00 Translation of the original documentation Publishing information B R Industrial Automation GmbH B R Strasse 1 5142 Eggelsberg Austria Telephone 43 7748 6586 0 Fax 43 7748...

Reviews: