![B&R Industries MASDL3CON-ENG User Manual Download Page 14](http://html1.mh-extra.com/html/bandr-industries/masdl3con-eng/masdl3con-eng_user-manual_460497014.webp)
System overview
14
SDL3 Converter User's manual V 2.00 Translation of the original documentation
3.5.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
5COSD3.1000-00
General information
LEDs
Status, SDL3
B&R ID code
0xE3C4
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
Interfaces
USB
Quantity
1
Type
USB 2.0
Variant
Type B
Transfer rate
Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s)
SDL/DVI-D interface
Variant
DVI-I
Type
SDL/DVI-D
SDL3 Out
Variant
RJ45, shielded
Type
SDL3
Electrical properties
Nominal voltage
24 VDC ±25%, SELV
1)
Nominal current
Max. 0.2 A
Overvoltage category per EN 61131-2
II
Galvanic isolation
Yes
Operating conditions
Pollution degree per EN 61131-2
2
Degree of protection per EN 60529
IP20
Ambient conditions
Temperature
Operation
0 to 55°C
2)
Storage
-20 to 60°C
Transport
-20 to 60°C
Relative humidity
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Vibration
3)
Operation (continuous)
2 to 9 Hz: 1.75 mm amplitude / 9 to 200 Hz: 0.5 g peak
Operation (occasional)
2 to 9 Hz: 3.5 mm amplitude / 9 to 200 Hz: 1 g peak
Storage
2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g peak / 200 to 500 Hz: 4 g peak
Transport
2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g peak / 200 to 500 Hz: 4 g peak
Shock
3)
Operation
15 g peak, 11 ms
Storage
30 g peak, 6 ms
Transport
30 g peak, 6 ms
Elevation
Operation
Max. 3000 m
2)
Mechanical properties
Housing
Material
Aluminum
Coating
White
Dimensions
Width
40 mm
Height
100 mm
Depth
80 mm
Weight
Approx. 500 g
Table 4: 5COSD3.1000-00 - Technical data
1)
EN 60950 requirements must be observed.
2)
The temperature specifications correspond to a specification at 500 meters. The max. ambient temperature is typically derated 1°C per 1000 meters starting
at 500 m above sea level.
3)
Top-hat rail clamp set X20AC0RF1 can also be used for improved installation / vibration resistance.
Vibration testing is performed per EN 60068-2-6. Shock testing is performed per EN 60068-2-27.