P. 27 - Replacement of HY-3 pack

OK

OK

Guard

Guard

Alarm

Alarm

Failure

Failure

HY-3

HY-3

Power ?

Power ?

BANDIT

Two allen bolts

to loosen the

side hatch

H

Y-

3

AN

T

B

DI

AN

T

B

DI

HY-3 pack grip

Allen key for red allen fixing bolts

Allen key for
unscrewing
side hatch

M8 thread end

H

Y-

3

B

A

N

D

IT

BANDIT

 240 DB 

v.206

Procedure to change the 

HY-3 pack

:

- First of all, the sabotage contact of the side
   hatch must be switched off. Through the 
   “Control Box” switch, 
   or if there isn’t a "Control Box"
   connected, by bridging the sabotage loop 

   

of the controlling alarm system.

- Unscrew by means of the "HY-3 pack grip" the side hatch
   by loosening the 2 allen bolts (there are anti loss rings 
   on the bolts).
- Remove the side hatch and put it gently (to avoid 
   scratches) on the unit.
- Open the box of the new 

HY-3 pack

  

 and put the upper layer next to the box. 

- Use the "HY-3 pack grip" allen key #5.  Unscrew  the 
   2 red allen-fixing bolts. Put these also on the 
   unit.
- Screw on the M8 thread end of the "HY-3 pack grip" 
   in the M8 hole and pull the "HY-3 pack grip", the whole
   

HY-3 pack

 will slide over the 2 slide pins out of the unit.

- Put the  “old 

HY-3 pack

” in the upper layer of the 

HY-3 pack

 box. 

  Unscrew the "HY-3 pack grip" and screw it on the new 
  

HY-3 pack

. Pull off the red transport protection cap and put it on the "old" HY-3 pack.

- Push evenly the 

HY-3 pack

 over the slide pins into the unit.  Press slightly on 

  to make sure the HY-3 pack connector and the liquid coupling are sliding over 

  

their respective connector and coupling.

- Unscrew the HY-3 pack grip and fasten both red allen fixing bolts.
- The green HY-3 pack LED will be on continuously (everything OK).
- Remount the side hatch and fix it by fastening both allen bolts. Put the sabotage switch
  of the side hatch back off (green LED switch and front LED “failure” go off).
- Repack the “old” 

HY-3 pack

 in the original box (tape it).

- For refilling: ship the box by normal freight to your 

BANDIT

-dealer. 

  Normally the returned 

HY-3 packs

 get a technical check, are refilled, memory reset and tested.

  Additional costs will be incurred if the returned 

HY-3 pack 

shows deep scratches or dents.

  Repair cost will be assessed by the company. The costs to repair the 

HY-3 pack

 

 into a reasonable condition

 

to sell, will be charged to your account. 

  

Changing the 

HY-3 pack

, takes about 5 

minutes. You will need a new 

HY-3 pack

 

and the 

HY-3 pack grip

, and possibly a 

ladder to reach a higher installed unit.

With each 

BANDIT 

comes a  "

HY-3 pack 

grip".

Summary of Contents for 240 DB

Page 1: ...installed in those rooms that contain the most valuable objects by doing so burglary damage is effectively limited to a strict minimum Advantages Fills 28 m of space per second of fog expulsion Extrem...

Page 2: ...holographic cameleon or broken white Standards Complies with European CE and EMC Standards Complies with International Standard IEC 839 1 3 Approved by the Belgian Ministry of Internal Affairs Complie...

Page 3: ...n supply fuse to off In case of doubt immediately contact your BANDIT dealer or manufacturer mentioned on the back cover of this manual There are no repairable components inside the appliance Leave al...

Page 4: ...or Str R0 version 60 aight ahead 28 m filling of space second with 25 cm eye object 16 BAR 1 6 Mpa 18 seconds 50 minutes from cold condition maximum 50 C and minimum 0 C 40 W hour 18 kW hour section 0...

Page 5: ...t in the direction of fragile objects The powerful fog expulsion could blow down these objects There has to be a free passage area for the ejected fog of at least 5 to 6 metres before it bounces again...

Page 6: ...or stuck to it with included double sided adhesive tape The device is installed at 6 cm off the floor to avoid possible damage due to cleaning tools or water Hidden mounting of the appliance For inst...

Page 7: ...shop of 180 m Fog image after 8 sec of fog expulsion The BANDIT 240 has a room filling capacity of 28 m per second This corresponds with 10 m sec The max surface area which can be secured with one de...

Page 8: ...is tamper secured so be sure that the unit is not in guard mode and that the control room optional is warned Connection to the mains power supply on the left beneath the PCB you ll find a 3 way termin...

Page 9: ...eds 12 V over input Red White Green Blue Orange Black 5 way connector remote control Red jump PaninV GrdinV F2 F3 F4 6 x Control box PCB connectors Technical output Guard output Alarm output Tamperloo...

Page 10: ...ns beneath connectors on PCB secured for possible polarity reverse and equipped with RC and LC filter an input has to be stable for at least 0 2 seconds before the new situation is accepted the connec...

Page 11: ...hout power supply Depending on the position of dipswitch A1 the guard mode will be active with 12 V supply over the input or active without power supply over this input As long as there is a 12 V supp...

Page 12: ...arm pulse over Alin1 after these 3 minutes will start a new fog expulsion period See also page 21 under temperature protection Configuration of the alarm input Alin Depending on the A2 dip switch posi...

Page 13: ...ther through 12 V supply or without power supply Depending on the position of dip switch A3 the panic mode will be active with 12 V supply or when there is no power supply over this input As long as t...

Page 14: ...current the voltage is 13 volt This voltage is practically ripple free 10mV ripple and is used as supply for small external power users such as external inner siren Jumbo LEDand PIR sensors It is als...

Page 15: ...per of rear cover If the tamper circuit is ok the red Tmp LED will go off as long as you keep the tamper spring pushed in b A HY 3 pack is in the unit and the side hatch is closed c there isn t connec...

Page 16: ...n HY 3 pack is above 50 C 4The temperature of the heat exchanger is too low to admit a fog expulsion This can mean a the internal over temperature fuse is interrupted b the heat resistance of the heat...

Page 17: ...unit is in guard mode The transistor output floats as long as the unit isn t in guard mode A common application for this handy Grdout output is to connect this output through a separating relay with...

Page 18: ...t The transistor conducts as soon as the unit switches to alarm mode or to panic mode The transistor output floats if a the panic mode is switched off or b automatically 3 minutes after the last fog e...

Page 19: ...d insulated and finished with a general insulation over the complete wire In the packing of the Control Box you ll find the mounting screws and nuts also a 6 way plug in connector with screw connectio...

Page 20: ...stays closed so no sabotage notice or fog expulsion while opening the side hatch The green LED on the switch is on The front LED internal failure blinks fast 2Hz This allows a fog ejection test each...

Page 21: ...ady F F One of tasks of the integrated Power Saver is to take care that the temperature of the heat exchanger will not raise higher than necessary to produce the adjusted fog quantity The temperature...

Page 22: ...4the environmental temperature of the HY 3 pack is above 50 C 4the MCU measures unreal values or value jumps on one or more of its sensors which indicates broken sensor s This red LED blinks fast 2 Hz...

Page 23: ...red error info LED Error on the PCB If this LED starts blinking a failure is reported whereby the frequency of blinking reveals the kind of failure The blinking sequence is built up in repeating time...

Page 24: ...ead out and executed The position of dip switches B1 and B2 determine the function of both channels ch1 and ch2 There are a total of 4 adjustment combinations Both transmitter buttons function if guar...

Page 25: ...nd or cold surfaces As soon there is an air flow ventilation this practically invisible and water soluble thin film will evaporate within 24 hours The lower the adjusted fog expulsion period the lower...

Page 26: ...ent HY 3 pack and calculates by means of the passed through parameters how much fluid still is available in theHY 3 pack If the level seems to have gone below the adjusted minimum value see page 22 HY...

Page 27: ...3 pack in the upper layer of the HY 3 pack box Unscrew the HY 3 pack grip and screw it on the new HY 3 pack Pull off the red transport protection cap and put it on the old HY 3 pack Push evenly the H...

Page 28: ...tem If a fog ejection test is performed you ll have to warn all persons in the immediate surroundings and the responsible person for fire hazard Make sure no one is looking at the direction of the eje...

Page 29: ...ia panic instantly persons who are over sensitive to stressing situations e g hyperventilate racing pulse etc persons who are strong asthmatic or exceptionally sensitive to irritation of the respirato...

Page 30: ...12V over Grdin So if relevant output of alarm system active npn transistor in conduction the GrdinV LED is lit and BANDIT is in guard mode A2 position OFF if there is a transition from 12V to 0 V ove...

Page 31: ...ng adjusted period dip block C Alarmcontact Tampercontact 12 V in _ PIR radar sensor Why to use a confirmation sensor To postpone the transition to alarm mode until a local zone detector confirms the...

Page 32: ...al is active relay contact closed GrdinV LED is lit and BANDIT is in guard mode A2 Position OFF if there is a transition of 12V to 0 V over Alin contact opens while BANDIT is in guard the alarm mode i...

Page 33: ...ods that are stolen even though BANDIT is functioning as supposed or if it is malfunctioning due to an internal or external failure We advise the installer to inform his insurance company that they wi...

Page 34: ...tion with BANDIT main PCB The purpose of these electronics is to measure how much fluid is present in the pressure vessel and to store all production and filling data of the HY 3 pack If the pressure...

Reviews:

Related manuals for 240 DB