P. 24 - Dip-switch adjustments
The PCB is equipped with a total of 10 dip switches, divided over 3 blocks, A, B and C.
To change an adjustment: first change position dip switch, than push-in ‘read’ switch (read).
Only after releasing this switch,
BANDIT
will read out and execute the new adjustments of the
dip switches.
Dip A2:
Configuration of alarm input [Alin1] (start pulse).
- Alarm mode starts as soon as there is 12 V over [Alin], dip A2 position ‘on’ (1).
- Alarm mode starts as soon as there is 0 V (no voltage) over [Alin],
dip A2 position ‘off’ (0).
Dip A3:
Configuration of panic input [Panin].
- Alarm mode as long as there is 12 V over [Panin], dip A3 position ‘on’ (1).
- Alarm mode as long as there is 0 V (no voltage) over [Panin],
dip A3 position’off’ (0).
Dip block B:
3 dips.
The unit is prepared to have connected an optional wireless remote control. This gives
you the opportunity to incorporate and to adjust easily a 2-channel receiver (order code
receiver: A/N 881, transmitter(s): A/N 891).
As soon as the female 5-way connector of the receiver is plugged-in on the male PCB
connector, the unit "knows" a remote control is present. Pushing in the read switch, the
adjustment of B1and B2 will be valid, read out and executed. The position of dip
switches B1 and B2, determine the function of both channels (ch1 and ch2). There are a
total of 4 adjustment combinations:
- Both transmitter buttons function if guard mode is on/off. Put B1 and B2 position ‘off’
(0). The normal guard input [Grdin] has no function anymore (ignored).
- Both buttons function if panic mode starts/stops. Put B1 position ‘off’ (0) and B2
position ‘on’ (1). The normal panic input [Panin] has no function anymore(ignored).
- Left button is guard mode on/off and right button is panic mode start/stop. Put B1
position ‘on’ (1) and B2 position ‘off’ (0). Normal guard input[Grdin] as well as normal
panic input [Panin] have no function anymore (ignored).
Dip block A:
3 dips, additional info inputs: see page 11 through 13
Dip A1:
Configuration of guard input [Grdin].
- Guard mode as long as there is 12 V over [Grdin], dip A1 position ’on’ (1).
- Guard mode as long as there is 0 V (no voltage) over [Grdin],
dip A1 position ‘off’(0).
ON
1
2
3
4
ON
1
2
3
4
BANDIT
240 DB
v.206
Through dip-switch adjustments, you can easily program the
needed features. Unlike other
BANDIT
models, which can be
programmed in a wide range through PC and/or remotely, the
adjustment through dip switches is very simple. This simple method
of adjustment, offers all needed elementary adjustment possibilities
which permits the unit to function in a very straightforward way.
Read
F