Sensor calibration |
H5000 Operation Manual
Dual Wind sensor
Set the quantity and source of wind sensor via the measured sources menu. After setting the
number and source of sensor ensure they are calibrated correctly. Follow the standard wind
sensor calibration procedure for each sensor.
¼
Note:
These options can be set via the H5000 Calibration menu on a compatible B&G Multi
Function Display (MFD)
Switching between wind sensors
The CPU handles sensor switching automatically.
MHU - Wind Sensor Sensor priority
MHU 1
(Wind sensor 1)
Used when the measured wind angle is less than 90º on MHU 1
MHU 2
(Wind sensor 2)
Used when the measured wind angle is greater than 90º on MHU 1
Environment
Sea / Air Temperature & Barometric pressure
If a suitable sensor is fi tted, the system will monitor the current sea / air temperature and
barometric pressure.
The off set value to be entered should adjust the reading from the sensor to match a
calibrated source, i.e. adjust sea temperature to match reading from a thermometer when
submersed in the water.