background image

6486-001 GB/2021-04

Operating Manual

3

High-performance ultrasonic baths

Applies to:

ZE 1031, ZE 1031 DT
ZE 1032, ZE 1032 DT
ZE 1058, ZE 1058 DT
ZE 1059, ZE 1059 DT

Dokument: 6486-001

Sprache: GB

Version: 2021-04

Summary of Contents for SONOREX ZE 1031

Page 1: ...86 001 GB 2021 04 Operating Manual 3 High performance ultrasonic baths Applies to ZE 1031 ZE 1031 DT ZE 1032 ZE 1032 DT ZE 1058 ZE 1058 DT ZE 1059 ZE 1059 DT Dokument 6486 001 Sprache GB Version 2021...

Page 2: ...2 36 6486 001 GB 2021 04 2021 1 2 GmbH Co KG Heinrichstr 3 4 12207 Berlin Ger many Tel 49 30 76880 0 Fax 49 30 7734699 info bandelin com Certified according to ISO 9001 and ISO 13485...

Page 3: ...uid 9 2 11 Erosion of the ultrasonic oscillating tank 10 2 12 Avoiding damage to the ultrasonic bath 10 2 13 Interference with wireless communication 11 3 Design and function 12 3 1 Design 12 3 2 Cont...

Page 4: ...ank 20 5 11 Enabling and blocking continuous operation ST 30 DT 21 5 12 Troubleshooting 21 6 Maintenance 22 6 1 Cleaning and care of the ultrasonic bath 22 6 2 Checks 22 6 3 Performing the foil test 2...

Page 5: ...his operating manual before using the ultrasonic bath In particular please observe chapter 2 Safety If you pass on this ultrasonic bath include this operating manual Contact your specialist dealer or...

Page 6: ...gents and indirect sonication to perform thorough cleaning 2 2 Use in medical field The intended medical purpose of the ultrasonic bath is the cleaning of instru ments Ultrasonic cleaning is performed...

Page 7: ...urface disinfection agent to avoid cross con tamination Reprocess accessories like holders carriers or baskets in a washer disinfector WD At higher working temperatures vapours and aerosols that are c...

Page 8: ...gthy ultrasonic operation Note the treatment times recommended by the ultrasound agent manufac turer Do not leave the ultrasound switched on for longer than necessary Do not reach into the sonication...

Page 9: ...s and you could breathe in vapours Place a lid on the ultrasonic bath during operation Use an extraction system if there are dangerous vapours Note the information on the label and on the safety data...

Page 10: ...und Do not use any chemicals in the ultrasonic oscillating tank that contain or release chloride ions This is the case with some disinfection agents house hold cleaning products and detergents Chlorid...

Page 11: ...cause interference in nearby wireless communication devices e g Mobile phones WiFi devices Bluetooth devices If interference with the functions of a wireless device occurs increase its distance from...

Page 12: ...Filling level mark 3 Control panel depending on model control panel ST 15 1 or control panel ST 30 DT 4 Ultrasonic generator 5 Drain optional here Viega fitting 3 2 Control panel for control unit ST...

Page 13: ...n bubbles are formed at the pressure minima At higher ambient pressures around the bubbles the bubbles collapse very quickly Strong localised microstreaming then occurs on the surfaces of the treated...

Page 14: ...4 Set up assembly 14 36 6486 001 GB 2021 04 4 Set up assembly The ultrasonic bath was assembled by authorised specialist staff using the assembly instructions...

Page 15: ...ontain an agent containing surfactant For accessories suitable for direct and indirect sonication see chapter 10 Accessories 5 2 Sonication fluid A solution made from water and a special ultrasound ag...

Page 16: ...on time from the agent man ufacturer To begin with select as short a sonication time as possible to protect the objects to be sonicated and the ultrasonic oscillating tank Check the result Lengthen th...

Page 17: ...On ultrasonic baths with a drain the drain must be closed The ultrasound must be switched off Procedure for direct sonication 1 Fill the ultrasonic oscillating tank with water up to 1 3 2 Pour the co...

Page 18: ...is switched off as soon as it reaches 0 3 To switch off the sonication turn the rotary knob for the sonication time to 0 The green indicator lamp goes off Information You can turn the rotary knob in...

Page 19: ...h the ultrasound on for degassing The degassing time is Volume of sonication fluid up to 10 litres 10 minutes Volume of sonication fluid over 10 litres 30 minutes Information The ultrasound noise beco...

Page 20: ...e sonication fluid Allow the goods to be treated to cool down before you touch them Switch the ultrasound off before you remove the goods to be treated Do not remove the goods to be treated with your...

Page 21: ...ay The green LED next to the symbol lights up to confirm this 5 12 Troubleshooting Fault Possible causes Remedy Ultrasonic effect too low loud noises Sonication fluid con tains gases There are too man...

Page 22: ...th a stainless steel cleaning product without scouring additives Do not use steel wool or scrapers to clean the ultrasonic oscillating tank Metal parts and rust particles in the ultrasonic oscillating...

Page 23: ...he effect of the ultrasound upon commissioning and at regular intervals We recommend a check every 3 months See chapter 6 3 Performing the foil test 6 3 Performing the foil test A foil test should be...

Page 24: ...this link https bandelin com folientest You will also find a video showing the application Furthermore the foil sheets can be archived in a suitable way scan photo etc Then you will be able to compar...

Page 25: ...c bath In addition the doc umentation template for the foil test can be filled in and archived 9 Rinse the ultrasonic oscillating tank thoroughly to remove loose foil particles You can order suitable...

Page 26: ...the ultrasonic bath before shipping if it has come into contact with toxic caustic radioactive or biologically hazardous substances Also clean and decontaminate accessories that you send in Download...

Page 27: ...roperly as electronic scrap if it can no longer be used Do not throw the ultrasonic bath in the household waste Observe the locally applicable regulations for disposing of electronic scrap The oscilla...

Page 28: ...peak output ultrasonic nominal output Power consump tion W A ZE 1031 DT GT 503 M C 1200 300 1 4 ZE 1032 DT GT 504 M C 1760 440 2 0 ZE 1058 DT GT 1003 M C 2400 600 2 7 ZE 1059 DT GT 1003 M C 2400 600...

Page 29: ...0 570 360 270 290 ZE 1032 DT TE 1032 510 300 200 220 20 570 404 270 290 ZE 1058 DT TE 1058 2 600 400 200 220 32 660 460 270 290 ZE 1059 DT TE 1059 600 400 200 220 32 660 504 270 290 Material Stainless...

Page 30: ...ion mains plug 2 m long mains cable for connection to the ultrasonic generator cold device connector 2 m long data cable for connection to the temperature sensor Degree of pro tection IP 30 Overvoltag...

Page 31: ...the goods to be treated are completely covered with sonication fluid in the tank Directly in the oscillating tank Indirectly in the oscillating tank STAMMOPUR DR 8 STAMMOPUR R STAMMOPUR GR 2 2 5 Disin...

Page 32: ...s steel sealing plug Inset basket K 29 EM order number 688 made of stainless steel mesh size 5 x 5 mm loadable up to 10 kg Basket holder KT made of stainless steel loadable up to 10 kg KT 30 order num...

Page 33: ...in baskets for gentle and contact free cleaning of sensi tive parts e g of microinstruments Fixation clamps FE 12 order number 117 A set made up of two large and five small clamps for fastening flexi...

Page 34: ...10 Accessories 34 36 6486 001 GB 2021 04...

Page 35: ...6486 001 GB 2021 04 35 36 Accessories 10...

Page 36: ...6486 001 GB 2021 04 1 2 GmbH Co KG Heinrichstr 3 4 12207 Berlin Germany Tel 49 30 76880 0 Fax 49 30 7734699 info bandelin com www bandelin com...

Reviews: