9
1.4.1
Tank size RM 110
RM 110 UH
RM 110 H
RM 110 U
RM 110
Exterior dimensions
(l × w × h)
mm
780 × 550 × 800
Interior dimensions
(l × w × d)
mm
600 × 450 × 450
Capacity l
135
Filling volume
l
125
Operating volume
l
110
Inlet and outlet
G 1 outside
Sprinkle tube inlet
Weir outlet
G ½ inside
G 1 outside
Heating power
W
4800
4800
-
-
Fuses (heating)
T12A
T12A
-
-
HF frequency
kHz
25 or 40
-
25 or 40
-
Fuses (generator)
T6A
-
T6A
-
Peak ultrasonic
output* W
4000
-
4000
-
HF power
W
eff
1000
-
1000
-
Weight (net)
kg
72,0
60,0
67,0
55,0
Order No. (40 kHz)
8230
-
8231
-
Order No. (25 kHz)
8240
-
8241
-
Order No. (without ultrasound)
-
8232
-
8233
* In order to improve the effect, the ultrasound is modulated, resulting in the HF power value increasing 4-fold as peak
ultrasonic power.