background image

13

Smart Pro, Smart & Secure

 installation instructions

13. Safety Testing

13.1 Test the Close Cycle

a. Press the OPEN button 

 or transmitter button to open the 

door (If the door starts closing, press the transmitter button to 

stop the door, then press transmitter again to open).

b. Place a piece of timber approximately 40mm high on the 

floor directly under the door.

c. Press the transmitter button to close door.  

d. The door should strike the object and re-open.

e. Remove the timber .

13.2 Testing the Open Cycle

a. Press the CLOSE button 

 or transmitter button to close the 

door.

b. Press the transmitter button again to open the door. 

c. When the door reaches approximately half way, firmly grab 

the door’s bottom rail -  the door should stop.

If the door does not reverse readily when closing, or stop when 

opening, put the door into manual by pulling down on the 

manual release string to diesengage the motor and contact 

13 62 63 for support.

13.3 Test the Manual Door Operation

A poorly maintained door could cause fatal / serious injuries or 

damage to property:

a. Frequently examine the door, particularly the cables, springs 

and mountings for signs of wear, damage or imbalance.  

DO NOT USE

 if repair or adjustment is needed since a fault in 

the installation or an incorrectly balanced door may cause 

injury.

b. Fasterners: Check all screws, nuts and bolts to ensure they 

are secure. 

c. Spring Tension: It is natural for springs to lose tension. Should 

the door become hard to operate or completely inoperative, 

contact a door professional. 

d. Guide Tracks: Clean the internal sections of the guide tracks 

every 3 - 6 months with a cloth dampened with mineral turps 

or methylated spirits.

e. Periodically disengage the opener and manually operate 

the door. The door must be smooth to operate by hand. The 

force required on the bottom rail should not exceed 20kg.

13.4 Test the Battery Backup

a. Press either the OPEN or CLOSE button to test the battery 

backup installation.

b. Whilst door is in motion, disconnect mains power. The door 

should continue to operate as normal.

c. Press either the OPEN or CLOSE button to activate the door. 

Whilst door is in motion, reconnect power. The door should 

complete the cycle as normal.

CAUTION: Take care when completing a 

safety test. Failure to follow this warning 

can result in serious personal injury 

and/or property damage.

WARNING! If the door is closing and is unable to  

re-open when obstructed, discontinue use Do not 

use a door with faulty obstruction sensing.  

Wood 40mm high

WARNING! If the door fails these tests, 

put the opener into manual mode, 

only operate the door by hand and 

call for service.

WARNING! Safety beams must be 

installed if the closing force at the 

bottom edge of the door exceeds 

400N (40kg).

When running from mains power and in 

operating mode, the battery condition 

can be tested by pressing and holding 

the STOP button for 4 secs.

tip

CAUTION! B&D App operation when 

power is out will depend on availability of 

Wi-Fi connectivity

Refer to Appendix A for LED status indicators for the 

Battery LED.

tip

Summary of Contents for Smart Pro SDO-9V3

Page 1: ...ion instructions Smart Pro Smart Secure These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161083_01 RELEASED 15 12 22...

Page 2: ...ny fixed controls permanently fix the label concerning the manual release adjacent to its actuating member after installation ensure that the mechanism is properly adjusted and that the drive reverses...

Page 3: ...ox 9kgs Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm gr...

Page 4: ...battery is swallowed or enters the body it can cause severe internal burns and can lead to DEATH in as little as 2 hours Always completely secure the battery compartment If the battery compartment do...

Page 5: ...rated angle which MUST be securely fastened to a structural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii does it have exposed beams The opener...

Page 6: ...o Extension Kit 3156mm Rail 1 Extension Kit 3946mm Rail 2 Extension Kits 4736mm Rail refers to 3160 rail 170mm 1 8 2 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protec...

Page 7: ...al supports otherwise opener failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profression...

Page 8: ...bt about the door s strength reinforcement may be added to the door s frame where necessary Door damage may occur if the bracket is installed on a panel with insufficient strength The opener s warrant...

Page 9: ...he beam 100mm above the ground level as per AS NZS 60335 2 95 2020 This can be achieved by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as...

Page 10: ...180mm 180mm Rated load 450N 400N 400N Maximum lifting under spring tension 200N 20kg 200N 20kg 200N 20kg Receiver type Multi frequency Multi frequency Multi frequency Receiver code storage capacity 6...

Page 11: ...e speed not suitable release button THEN HOLD Each press changes speed as per table MAIN LIGHT BEEPER SPEED MODE x 3 3 x FAST Default x 2 2 x MEDIUM x 1 1 x SLOW RELEASE When at desired speed S T E P...

Page 12: ...D lit Press repeatedly R E P R O F I L I N G T H E D O O R HOLD for 2 secs Door will open and close Re profiling is a simple way of re learning the travel characteristics of a previously setup Limit S...

Page 13: ...e tension Should the door become hard to operate or completely inoperative contact a door professional d Guide Tracks Clean the internal sections of the guide tracks every 3 6 months with a cloth damp...

Page 14: ...after hitting an obstruction or stalling ii Safety Beam triggered auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is t...

Page 15: ...S O R I E S Alignment Mode is entered Ensure Alignment For PE Beams HOLD for 2 secs till 3 beeps are heard OFF Then replace controls cover Re registering is required every time an accessory is remove...

Page 16: ...a pen HOLD for 2 sec the middle button through the coding hole S T E P T H R E E Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Take new remote RELEASE S T E P F I V E Press to test Opene...

Page 17: ...emove controls cover till remote LED lit Press repeatedly I N S T A L L I N G W A L L R E M O T E C O N T R O L S T E P T W O HOLD Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Release bo...

Page 18: ...connecting to wifi Remove controls cover Press repeatedly LED will turn PURPLE HOTSPOT ON S T E P T H R E E Open APP and click START W A R N I N G This device allows for operation of the door when not...

Page 19: ...D I S E N G A G E T H E O P E N E R 2 0 M A N U A L D O O R O P E R AT I O N C A U T I O N W h e n t h e o p e n e r i s m a n u a l l y d i s e n g a g e d t h e d o o r i s n o l o n g e r l o c k e...

Page 20: ...r stopped 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow Illuminates when battery is charged and flashes when bat...

Page 21: ...ter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter throug...

Page 22: ...E beam being blocked on closing hit an obstruction etc Also can occur if battery is activated x 4 or x 5 Position Fault x 6 Motor driving in wrong direction x 7 Memory fault x 8 Motor current sensor f...

Page 23: ...ening of door mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure...

Page 24: ...old waste facilitates the recovery of organic materials through alternative waste technologies such as composting Batteries and heavy metals are known contaminants in compost The community supports re...

Page 25: ...Y LED off Battery not used not fitted solid Battery charged flash 2 secs in use holding STOP for 10s will shutdown flashing Battery charging when connected to power rapid flashing Battery failed fault...

Page 26: ...E N T M O D E I N S T R U C T I O N S S T E P T W O S T E P F O U R If no beep is heard max or min setting is reached Press to move through options as per table below OR Observe the number of flashes...

Page 27: ...to save Then refit controls cover Press to exit Remove controls cover till gear LED flashing Press repeatedly When activated PET mode drives the door to a preset position from the close position there...

Page 28: ...CLOSE limit should be when rubber strip touches the ground to Close S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as thi...

Page 29: ...ia Pty Ltd 29 your representative is Smart Pro Smart Secure installation instructions G Setting up Tilt Door Prior to limit set up the opener can be set to J Type Tilt Profile This process allows the...

Reviews: