12
Smart Pro, Smart & Secure
installation instructions
NOTE: If unhappy with the speed or travel limit setting,
restart this procedure by resetting the door limit positions
as per below first.
12.2 Clearing the Door Limit Positions
S T E P O N E
S T E P T W O
S T E P T H R E E
Remove controls cover
till gear
LED lit
Press
repeatedly
C L E A R I N G T H E D O O R L I M I T P O S I T I O N S
HOLD
for 10 sec
Release when
light stops
flashing
The BLUE LED flashes
continuously to show
limits cleared
NOTE: No action taken within
30 secs, the opener returns to
original settings.
SET Close & Open limits
12.3 Re-profiling the Door
S T E P O N E
S T E P T W O
Remove controls cover
till gear
LED lit
Press
repeatedly
R E - P R O F I L I N G T H E D O O R
HOLD
for 2 secs
Door will open
and close
Re-profiling is a simple way of re-learning the travel
characteristics of a previously setup Limit Switch
travel. Re-profiling is used when travel characteristic
change due to mechanical adjustments.
tip
To initiate a re-profile: LIMITS must already be set.
S T E P T H R E E
OFF
Then refit
controls cover
Press
to exit
12.4 Controller memory reset
To clear the controller:
S T E P O N E
S T E P T W O
When in limit setting mode
C O N T R O L L E R M E M O R Y R E S E T
HOLD
for 10 sec
Release
The BLUE LED flashes
continuously to show
limits clear
This will cause all control memory to be set to factory defaults
EXCLUDING: transmitters, history log and cycle counters.
If limits are already set, clear limits first by following
Clearing the door limit positions and then follow
below.
tip