15
PanelMax
installation instructions
14.2 Terminal Block
Wired accessory items can be connected to the terminal block
J4
.
Terminal connections from top down are as follows:
a. +35V
(Auxillary)
b. AUX
(Auxillary)
c. SB
(Safety Beam input, mandatory);
d. GND
(Common ground for accessories and Safety Beam);
e. GND
(Common ground)
f. OSC
(Open/Stop/Close trigger)
14.3 Connecting or Disconnecting Accessories
The opener can hold up to 4 accessories. For example Secure;
• Auto-Lock
• Wireless PE Beams
• Smart Hub
If an Auto-lock and Wireless PE Beams are both installed
ensure that the channels on the base stations on each
device are different. The channel on the base station
can be changed by sliding the switch in either direction
tip
S T E P O N E
S T E P T W O
S T E P T H R E E
Remove controls cover
till gear
LED lit
Press
repeatedly
C O N N E C T O R D I S C O N N E C T A C C E S S O R I E S
Alignment Mode is
entered.
Ensure Alignment.
For PE Beams
HOLD for 2 secs
till
3 beeps
are heard
OFF
Then replace controls cover
Re-registering is required every time an accessory is removed.