1
GEZE TS1
2
00 Overhead
Door Closer
WARNING:
DOOR CLOSERS WITH A POWER
RATING LOWER THAN 3 OR WITH MECHANICAL
HOLD OPEN DEVICES ARE NOT SUITABLE FOR
USE WITH FIRE DOORS.
Components Checklist:
1x Closer body & cover
1x Guide Rail Assembly
2x M6 Allen Bolts
2x Plastic end caps
1x Plastic spindle cover
4x 5x55mm Self-tapping countersunk screws
2x M5x40mm Countersunk screws
4x M5x55mm Countersunk screws
2x 5x50 Self-tapping countersunk screws
Tools Required For Installation:
Flat head screwdriver
Posidrive screwdriver
Power drill
4.2mm drill bit
Template (supplied)
Pencil
10mm Spanner
5mm Allen key (supplied)
M5 Tap and Tap wrench
(steel door mounting)
User Information for Door Closers
This information must be observed. Non compliance
will absolve the manufacture from any liability. The
door closer must only be used in accordance with its
intended use; i.e. closing of side hung doors
following manual opening.
Incorrect use may cause injury
¾
Obstruction of closing process (e.g. dragging
doors, sticking weather strips/sealing rubbers, rough-
running locks)
¾
Incorrect installation and adjustment (e.g.
slamming doors)
¾
Danger of finger trap between frame and door leaf.
¾
Wrong size door closer.
¾
Closer used for other purpose than to close side
hung doors.
Maintenance:
NOTE:
¾
Maintenance to be carried out by a specialist only.
¾
Check assembly for tolerance and undue wear.
¾
Tighten any screws that may have become loose.
At least once a year:
¾
Grease moveable parts.
¾
Check operation of doors and adjust if necessary.
¾
For door closers subject to release by Electro
Mechanical and Electro Hydraulic means ensure that
local regulation are adhered to.
Installation and adjustment by specialist only
Where necessary, an additional doorstop or buffer
must be fitted to limit the maximum opening of the
door. This is of particular relevance for slide rail
closers where the opening angle may be limited by
frame. For further explanations see catalogue
preface and product information.
Door handing - DIN left / right
Stand facing the door on the hinge side / pull side. If the hinge or
pivot is to your right hand side the door is considered to be DIN
right. If the hinge or pivot is to your left hand side the door is
considered to be DIN left.
IMPORTANT WARNING:
HIGH INTERNAL PRESSURES, UNDER NO CIRCUMSTANCES
ATTEMPT TO DISMANTLE THE CLOSER.
215
52
Spindle
TS1
2
00 BODY
PRIMARY ARM
SECONDARY ARM
135
approx.
250
58
16
20
Closing speed valve
TS1000 PARALLEL ARM BRACKET
95
28
4
Latch action valve
21
44
Installation Instructions