25
PanelMax
installation instructions
B - Adjustment Mode Instructions
Parameter
Value options = Indicated by brightness
of main light
1
2
3
4
5
6
MARGIN
x1
1.0A
1.2A
1.4A
1.6A
2.0A
-
PE AUTO-CLOSE
x2
OFF
15sec
30sec
60sec
90sec
-
AUTO-CLOSE
x3
OFF
15sec
30sec
60sec
90sec
120sec
LIGHT TIMER
x4
30sec
60sec
90sec
120sec
180sec
240sec
AUX OUTPUT
x5
Mimic
light
1sec
30sec
60sec
120sec
180sec
240sec
300sec
600sec
toggle
When parameter edit
mode is active, if any
button other than MODE is
pressed, then when MODE
is pressed again, operating
mode will be selected
instead of the NETWORK
adjustment mode.
tip
AUX OUPUT
• Configures how the AUX Output operates. If
configured for Mimic light mode then the AUX
output will activate whenever the main light
output is on.
• All other settings require either a remote control
code set to the AUX function or the Phone App to
be used to activate the output.
• The time settings option indicates how long
the output will remain on when triggered. If the
output is already on, then a 2nd trigger will turn
the output off.
• The toggle On/Off setting does not use a timer
and the output simply changes state on each
trigger..
S T E P O N E
S T E P T H R E E
Remove controls cover
till gear LED
starts flashing
Press
repeatedly
A D J U S T M E N T M O D E I N S T R U C T I O N S
S T E P T W O
S T E P F O U R
If no beep is heard, max
or min setting is reached.
Press to move
through options as
per table below
OR
Observe the number
of flashes to indicate
the parameter.
Press
to enter
parameter
the remote LED is
lit when editing
active
OR
Use either button to
scroll through
Pressing the MODE button when a parameter is
being adjusted will load the default value.
tip
Press to save
OR
Press to leave
unchanged
Press to
exit
Operating MODE is
entered after 5 secs,
unless a new
adjustment is started
or saved.
S T E P F I V E
S T E P O N E
S T E P T H R E E
Remove controls cover
till gear LED
starts flashing
Press
repeatedly
A D J U S T M E N T M O D E I N S T R U C T I O N S
S T E P T W O
S T E P F O U R
If no beep is heard, max
or min setting is reached.
Press to move
through options as
per table below
OR
Observe the number
of flashes to indicate
the parameter.
Press
to enter
parameter
the remote LED is
lit when editing
active
OR
Use either button to
scroll through
Pressing the MODE button when a parameter is
being adjusted will load the default value.
tip
Press to save
OR
Press to leave
unchanged
Press to
exit
Operating MODE is
entered after 5 secs,
unless a new
adjustment is started
or saved.
S T E P F I V E
DEFAULT parameter
(underlined)
tip
LIGHT TIMER
• Adjusts the time the main light will remain on after
the door is operated or a remote control code set