background image

OPERATING CONTROLS

6

2

4

V

A

C

S

U

P

P

L

Y

P

R

O

G

P

.E

M

O

T

O

R

1)

P.E. BEAM INPUT

2)

DOOR STATUS LED (YELLOW)

3)

DATUM ADJUST SCREW

4)

DOOR CODE BUTTON (BLACK)

5)

CODING LED (RED)

6)

SET BUTTON (ORANGE)

7)

OPERATE BUTTON (BLUE)

8)

FORCE MARGIN SET BUTTON

9)

PLUS BUTTON 

(FOR LIMITS SETTING & FORCE MARGIN)

10)

OPEN LIMIT LED (GREEN)

11)

MINUS BUTTON 

(FOR LIMITS SETTING & FORCE MARGIN)

12)

CLOSE LIMIT LED (RED)

13)

MANUAL RELEASE HANDLE

1

2

3

4

5

6

7

8

10

11

12

13

9

©Copyright 2006 B&D Doors

Summary of Contents for EconoLift

Page 1: ...ure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please save these instructions for future reference RDO 2 v1EL EconoLift AUTOMATIC ROLLING GARAGE DOOR OPENER Econolift Econolift ROLLING GARAGE DOOR OPENER ...

Page 2: ...staller Information Factory Default Settings Technical Specifications Trouble Shooting Guide Parts List Warranty 3 4 5 6 8 9 9 9 10 11 11 12 13 13 14 14 14 15 15 15 16 16 16 17 17 18 19 B D Doors to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an B...

Page 3: ...ning It is vital for the safety of persons to follow all instructions Failure to comply with the following Safety Rules may result in serious personal injury and or property damage The unit is rated to IP24 however it should be installed so that it is protected from the elements Where possible it should not be exposed to water or rain It is not to be immersed in water or sprayed directly by a hose...

Page 4: ...LLIGENT FORCE MARGIN SAFETY OBSTRUCTION SYSTEM While the door is performing a close cycle should it hit an obstacle or be restricted in some manner it will automatically reverse The amount of force the door should encounter before reversing is automatically adjusted by the doors control system during the initialisation of the automatic door opener The door will also stop if restricted whilst openi...

Page 5: ... force The Force Margin Set is only ever used if other environmental factors wind etc affect the operations of the door opener PLUS button green can be used during installation to set the open limit position Pressing this button will move the door in the open direction Movement stops when the button is released NOTE The open safety obstruction detection is inoperable whenever the Close Drive butto...

Page 6: ...ODE BUTTON BLACK 5 CODING LED RED 6 SET BUTTON ORANGE 7 OPERATE BUTTON BLUE 8 FORCE MARGIN SET BUTTON 9 PLUS BUTTON FOR LIMITS SETTING FORCE MARGIN 10 OPEN LIMIT LED GREEN 11 MINUS BUTTON FOR LIMITS SETTING FORCE MARGIN 12 CLOSE LIMIT LED RED 13 MANUAL RELEASE HANDLE 1 2 3 4 5 6 7 8 10 11 12 13 9 Copyright 2006 B D Doors ...

Page 7: ...ER 1 WEIGHT BAR NOT INCLUDED IN SOME MODELS 1 PAN HEAD SCREW M4x50mm NOT INCLUDED IN SOME MODELS 2 NILOCK HEX NUT M4 NOT INCLUDED IN SOME MODELS 2 FLAT WASHER I D 3 16 x 1 2 NOT INCLUDED IN SOME MODELS 2 LOCKING BAR COVERS 2 INSTALLATION MANUAL 1 Copyright 2006 B D Doors TRANSMITTER ...

Page 8: ...ck or bind in the guide tracks The ideal operational effort in raising or lowering the door should not exceed a force of 10kg 22 lbs Make sure that all door locks ropes chains etc are either released or disabled and remove unnecessary accessories 2 FIXING OF DOOR WEIGHT BAR Move the door manually to the mid open position Place the weight bar on the bottom rail in the middle of the door and secure ...

Page 9: ... the right hand door mounting bracket from wall 6 Remove the drive assembly from the packaging Try to rotate the drive gear by pushing on the fork If the gear does not rotate the manual mode has to be selected To select pull downward on the string handle then release slowly The drive gear should now rotate freely 7 Slide the drive assembly over the door axle making sure that the fork extends into ...

Page 10: ...NG DOOR TRAVEL LIMITS IMPORTANT NOTE The OPERATE button will not function until the open and close limits positions are set 6 1 SETTING DATUM POSITION 1 Switch the opener into manual mode Fig 8 2 Move the door by hand to an approximately mid open position 3 Re engage the opener 4 Using a small blade screw driver turn the datum adjust screw slowly until the yellow status LED just illuminates Note I...

Page 11: ...lly once step 4 is performed The door will also automatically re open after fully closing with a short pause between the cycles 4 Press Set button to store the open limit position into memory The door will now automatically close to its limit position then fully open to calculate the safety obstruction forces Please be aware of the above warning 7 RESETTING DOOR LIMITS POSITIONS The door limit pos...

Page 12: ...ess and hold the Force Margin Set button Fig 11 2 While holding down the Force Margin button press the Plus button Each press increases the force margin in both directions The Open Limit LED will illuminate each time the Plus button is pressed Each press increases the force margin Test the force as per step 8 1 and 8 2 If the Open Limit LED flashes continuously when the Plus button is being presse...

Page 13: ...en or screwdriver Fig 14 3 Replace covers and program this code 10 3 SETTING ENTRY KEYPAD TRANSMITTER CODE 1 Make sure that the battery is set in the Key Pad Transmitter 2 Press the Code Set button on the opener the Code Set LED will illuminate to indicate the opener is in Code Learn mode if a valid code is not stored within 15 seconds the opener will exit Code Learn 3 For an entry keypad the desi...

Page 14: ...te The door may move uncontrollably if the spring tension is weak or not set properly or the door is unbalanced If this occurs do not use the door and contact your installer for service The manual release handle can be locked to prevent unwanted disengagement where fitted This is useful if the opener is mounted on an exposed carport or perimeter door To disable the manual release turn the key cloc...

Page 15: ...ode Codes a transmitter button for OPERATE function Force Margin Set Plus Increases the obstruction force margin setting Force Margin Set Minus Decreases the obstruction force margin setting Force Margin Set then Set Reloads the factory set default obstruction force margin setting Close for 6 Secs Clears the door limits set positions Limits then need to be reset Set then power on hold until all LE...

Page 16: ...ed No of CODE COMBINATIONS Over 3 86 Billion Codes TRANSMITTER BATTERY 2 x 3V Type 2032 Button Cell DEFAULT SETTINGS AND SPECIFICATIONS 16 Note 1 The maximum continuos curtain residential roll up door opening that the EconoLift can be installed on is 5500mm wide by 2700mm high The door must be well balanced A person of average strength should be able to lift up the door manually with very little e...

Page 17: ... tracks Possible obstruction in the doorway Increase force margin setting See Step 8 3 on page 13 Or re calculate force margin See Step 8 6 on page 13 Remove obstruction Door operates from drive unit OPERATE button but not from transmitter See note Transmitter code not stored in memory Flat Battery Code transmitter in to openers memory Refer Step 9 1 on page 14 Replace battery Door will not open o...

Page 18: ...E BRACKET CLUTCH GEARED MOTOR ASSY 12 01 WS TRANSFORMER TDB 72 01 KIT 72VA RATCHET TIMING ASSY POWER CORD A S 1 5M 2P1R FELT 21 X 29 TERMINAL BLOCK 500 02DS 2 POS CAP POLYFILM 0 1UF K X2 275 VAC HEX SERRATION HEAD SCREW M8X16 TAPTITE SCREW P M4X10 PAN HEAD SCREW W WASHER M4X8 TAPTITE SCREW P BLACK ZNC M3X14 INTERNAL TOOTH LOCK WASHER I D 3 CABLE TIE 4 GT 100M STRING HANDLE ASSY CONTROL BOARD CB 17...

Page 19: ... call made by B D or an Authorised Distributor where such a call is made for the purpose of adjustment as described in the Manufacturers Written Instruction Manual and not for rectification of a defect pursuant to the warranty hereunder 8 i The Purchaser shall be responsible for any expense incurred by B D or an Authorised Distributor in ensuring that the Opener is readily accessible for any repai...

Page 20: ...odifications or repairs made or attempted to be made by any unauthorised person vii Faulty electrical wiring of structures to which the Opener is affixed viii Radio or other electronic interference including citizen band transmissions ix Water damage 11 The warranty contained in Clause 3 does not cover batteries or globes and B D shall not be liable for any defect malfunction or failure of such it...

Reviews: