PARAMETERS
15
DOOR STATUS INDICATORS
DOOR OPENER STATE
OPEN LED
GREEN
CLOSE LED
RED
DOOR STATUS
LED YELLOW
BEEPER
OPEN
ON
CLOSE
ON
OPENING
FLASHING
CLOSING
FLASHING
DOOR TRAVEL STOPPED
FLASHING
FLASHING
DOOR OBSTRUCTED WHEN OPENING
FLASHING
DOOR OBSTRUCTED WHEN CLOSING
FLASHING
BEEPS WHILE
DOOR IS MOVING
OPENER OVERLOADED
ALTERNATING
FLASHES
ALTERNATING
FLASHES
MAINS POWER INTERRUPTED
RAPID
FLASHES
BUTTONS
FUNCTION
OPERATE
Opens/Stops/Closes the door
Door Code
Codes a transmitter button for OPERATE function
Force Margin Set + Plus (+)
Increases the obstruction force margin setting
Force Margin Set + Minus (-)
Decreases the obstruction force margin setting
Force Margin Set (then) Set
Reloads the factory set default obstruction force margin setting
Close for 6 Secs
Clears the door limits set positions. Limits then need to be reset.
Set (then power on) & hold until all LEDs are off
Deletes control parameters excluding transmitter storage memory.
Door Code (then power on) & hold until all LEDs are off
Deletes all transmitter stored in memory.
Set for 2 sec.
Re-initialises the Opener to re-calculate force margins