B&B Electronics, Inc.
SPECTRE Configuration Manual
79
710-10001-02 Rev. 3.0
www.bb-elec.com
www.bb-europe.com
1.32. Set real time clock
You may update the router
’s internal clock at any time using a NTP server by selecting
the
Set Real Time Clock
menu item. Enter the IP address or domain name of the NTP Server
and click
Apply
to set the clock.
Fig. 68: Set real time clock
1.33. Set SMS service center address
The SPECTRE RT industrial router does not support the
Set SMS service center
address option
.
The SMS service center phone number is normally programmed into the SIM card by the carrier
and does not need to be manually entered. However, in some cases, it may be necessary to set
the phone number of the SMS service center in order to send SMS messages. This parameter
cannot be set if the SIM card already contains the SMSC information. The phone number can be
entered with or without an international prefix. For example: +420 xxx xxx xxx. If you are unable
to send or receive SMS messages, contact your carrier to find out if this parameter is required.
This parameter is provisioned automatically by the carrier on CDMA networks and does not
need
to
be
manually
entered.
Fig. 69: Set SMS service center address
1.34. Unlock SIM card
The SPECTRE RT industrial router does not support the
Unlock SIM card
option.
You may lock the SIM card with a 4-8 digit PIN (Personal Identification Number) code to
prevent unauthorized use of the SIM card. The PIN code must be entered each time that the
SIM card is powered up. The SPECTRE cellular router supports the use of a SIM card with a
PIN number. Enter the PIN number into the SIM PIN field on the configuration page and select
Apply
.
Access to the SIM card is blocked if the PIN code is incorrectly entered 3 times. Contact
technical support if the SIM card has been blocked.
Fig. 70: Unlock SIM card