background image

 

 

 

BAND-IT-IDEX, Inc. 
A Unit of IDEX Corporation 
4799 Dahlia Street 
Denver, CO 80216-3070 USA 
P: 1-800-525-0758 
F: 1-800-624-3925

 

Document # P46050 rev. - 

© Copyright 

BAND-IT-IDEX, Inc. 2008 

All rights reserved 

www.BAND-IT-IDEX.com 

 

Page 2 of 4 

GRC001 Hand Tool

JR Adapters: The JR adapters (J00169 and J05069 heavy duty) are used with the BAND-IT GRC001 tool when 
BAND-IT JR. preformed clamps are used. 
 
C04388 Close Quarter Tension Nut: In cramped quarters, use instead of tool tension handle. 
 
NOTE: See general catalog or web site for instructions and ordering information. 

Gripper Cleaning Instructions: 

Cleaning and 
Accessories 

1. Remove gripper. Align gripper pin 
hole with notch in tool frame. Using a 
punch and hammer, punch pin out of 
slide block. 

2. Using a wire brush, clean all 
foreign matter from teeth. 

Scru-Lokt Buckles: 

1. The BAND-IT Scru-Lokt clamp, 
using the Scru-Lokt buckle, is 
applied in exactly the same way as 
the BAND-IT clamp except that the 
tool is not rolled over. 

Tool Accessories: 

3. Where stub of band is left 
for Scru-Lokt clamp, it may be 
folded under as shown. 

2. After tension is applied, insert set screw in 
Scru-Lokt buckle and tighten. To permit 
taking up Scru-Lokt clamp, or to re-use, a 3 
inch (7.5 cm) stub should be left so that tool 
will be able to re-grip band later. 

3. Replace pin. Gripper spring must be 
seated in tension screw hole. Align 
gripper hole with slide block hole, insert 
pin in hole and hammer pin in place. 

Reviews: