Operating
Manual
Tool Calibration Operation Instructions:
1.
Do not adjust tools outside their tension range.
2.
Cut-off switch must be turned off prior to calibration.
3.
Attach proper tool adapter (Table 3) to Calibration Device (E1000) using screws
and hex key provided as shown below.
4.
Insert Test Band into Calibration Device through the adapter slot while pull the
Hold Down Lever on the Calibration Device forward, (Fig. 10a) until it stops.
5.
Insert free end of test band into tool. Be sure to keep tool and calibration device
aligned straight. Tool head must be inserted into adapter properly.
Fig. 11a
Fig. 11b