5.4    Cleaning 
 

-

  Stop providing liquid and release pressure in the fluid chamber. 

-

  Connect the cleaning line to fluid inlet port and add pressure. 

-

  According to chapter 4.2, dispense cleaning liquid instead of fluid. 

 

5.5    List of spare parts 
 

No. 

Name 

No. 

Name 

Seal cap 

10 

O-ring P6 

O-ring P4 

11 

Cylinder rod 

O-ring P14 

 

 

 
 
 

6. Trouble shooting 

 
 
 

Item 

Cause 

Treatment 

Cylinder rod(11) does not work. 

Supply the air into valve on/off line. 

The fluid is cured. 

Clean the valve.(see chapter 5.4) 

Pressure the fluid reservoir. 

The fluid does not supply. 

Supply the fluid. 

No dispensing 

The controller is turned off. 

Turn on the controller. 

The needle adapter(1) is 
unfasten. 

Clean the valve.(see chapter 5.4) 
And fasten the adapter(1). 

Fluid leakage 
from needle 
adapter(1) 

The Cylinder rod(11) is worn 
out. 

Clean the valve.(see chapter 5.4) 
And replace the rod. 

Fluid leakage 
between under 
cap(3) and 
middle cap(7) 

The lifetime of seal cap(4) and 
o-ring(5) is end. 

Clean the valve.(see chapter 5.4) 
And then replace seal cap(4) and   
o-ring(5). 

 