6
5. Maintenance & Cleaning
5.1 Storing after use
-
To avoid the nozzle tip contact air, put an end-cap on the nozzle or keep
a nozzle in the grease.
-
Perform the cleaning process(see Chapter 5.4).
5.2 Check items while operating
-
Make sure that air supply is in good condition.
-
Check other connecting appliances that are properly turned off.
-
Be sure that end of nozzle is not clogged with hardened fluid.
5.3 Exploded view
-
The user’s arbitrary disassembly is not recommended.
1
Needle adapter
BS
9
Cylinder housing
A6061
2
Wrench bolt
M3x15L 10
O-ring
P6
3
Under cap
SUS303 11
Cylinder rod
SUS303
4
Seal cap
Teflon
12
Spring
SUS303
5
O-ring
P4
13
Upper cap
A6061
6
Wrench bolt
M3x20L 14
Nut
SUS303
7
Middle cap
A6061
15
Adjustment bolt
SUS303
8
O-ring
P14