Section 8: Repairs
Bambi MAX Service Manual
– Models HL4000-HL9800 41
2.
Place the valve inside the valve-guard. Rotate the
valve until the control box and actuator are in the
position shown.
3.
Install the four 3/8" bolts on the base of the valve.
Some rotation may be necessary to line up the
standoffs to the bottom plate holes.
4.
String the control cable. Before unrolling the coil of
cable, pass it through the center of the IDS hub.
5.
Stretch the control cable out between the shell and the
head. Check to make sure you have at least 6" of slack
in the control cable before attaching the cable to the
head with four tie wraps.