Scale Indicator Not Working/Error Codes
1 Scale indicator does not want to power up after pressing the power button:
A Check that the host indicator is turned on
B Check the PWR/COM connection on the bottom of the indicator
C Check the PWR/COM connection on the bottom of the host indicator
D Check electrical connection at the 12VDC switched source
E Check the PWR/COM cable for any breaks or damage and replace if necessary
2 Scale indicator showing error code:
Display
Problem
Definition
Internal Programming
Lost or Corrupted
Calibration programming is stored in a permanent memory area This
code indicates an error in the stored settings Attempt to recalibrate the
indicator If error still present after recalibration, the indicator will need to
be replaced
Weighing Capacity
Error
The scale indicator is over the maximum weight capacity This typically
indicates either a load cell issue or a cable issue Checking the scale
indicator will determine which load cell(s) have lost communication with
the scale indicator
Low Battery
The supply voltage to the indicator is below proper operating level Check
all power connections and source voltage
Unable to Display
Value
The number that is wanting to be displayed has too many characters for
the display to show The typical cause of this error is zeroing out the scale
with a full load so when the load is emptied, the negative number has too
many characters Zeroing the scale will clear this error
Load Cell Error
Detected at Power Up
A load cell may have failed or a bad connection exists between the load
cell and the scale The number will show which cell(s) to check See the
Load Cell Conversion Chart below for cell failure code
Check cables and connections between indicated load cells
Load Cell Error
Detected during
Operation
A load cell may have failed or a bad connection exists between the load
cell and the scale The number will show which cell(s) to check See the
Load Cell Conversion Chart below for cell failure code
Check cables and connections between indicated load cells
Analog/Digital Circuit
Board Failure
The analog to digital circuit board inside the indicator has failed and needs
to be repaired or replaced
Load Cell Conversion Chart
When receiving an LCb or an LC error, find the corresponding error code on the table below to identify the load cell(s) causing
the error A letter “E” below the Load Cell Number indicates that load cell is causing an error with the scale indicator and needs
to be checked
Error
Code
Load Cell Number
6 5 4 3 2 1
Error
Code
Load Cell Number
6 5 4 3 2 1
Error
Code
Load Cell Number
6 5 4 3 2 1
Error
Code
Load Cell Number
6 5 4 3 2 1
1
- - - - - E
0F
- - E E E E
21
E - - - - E
31
E E - - - E
2
- - - - E -
11
- E - - - E
22
E - - - E -
32
E E - - E -
3
- - - E - -
12
- E - - E -
23
E - - - E E
33
E E - - E E
4
- - E - - -
13
- E - - E E
24
E - - E - -
34
E E - E - -
5
- E - - - -
14
- E - E - -
25
E - - E - E
35
E E - E - E
6
E - - - - -
15
- E - E - E
26
E - - E E -
36
E E - E E -
03
- - - - E E
16
- E - E E -
27
E - - E E E
37
E E - E E E
05
- - - E - E
17
- E - E E E
28
E - E - - -
38
E E E - - -
TROUBLESHOOTING
Summary of Contents for FIELD FLOATER 6
Page 2: ...Serial Number Date of Purchase Purchased From Dealer s Address Dealer s Telephone ...
Page 4: ......
Page 8: ...4 Field Floater 6 Grain Cart User Manual ...
Page 9: ...Field Floater 6 Grain Cart User Manual 5 Safety ...
Page 15: ...Field Floater 6 Grain Cart User Manual 11 Technical Data ...
Page 18: ...14 Field Floater 6 Grain Cart User Manual ...
Page 19: ...Field Floater 6 Grain Cart User Manual 15 Operation ...
Page 39: ...Field Floater 6 Grain Cart User Manual 35 Maintenance ...
Page 52: ...48 Field Floater 6 Grain Cart User Manual ...
Page 53: ...Field Floater 6 Grain Cart User Manual 49 Troubleshooting ...
Page 60: ...56 Field Floater 6 Grain Cart User Manual ...
Page 61: ...Field Floater 6 Grain Cart User Manual 57 Weigh System Programming ...
Page 78: ...74 Field Floater 6 Grain Cart User Manual ...
Page 79: ...Field Floater 6 Grain Cart User Manual 75 Notes ...
Page 80: ...76 Field Floater 6 Grain Cart User Manual Date Notes NOTES ...
Page 81: ...77 Field Floater 6 Grain Cart User Manual Date Notes NOTES ...
Page 82: ...78 Field Floater 6 Grain Cart User Manual Date Notes NOTES ...
Page 83: ......
Page 86: ...Serial Number Date of Purchase Purchased From Dealer s Address Dealer s Telephone ...
Page 88: ......
Page 91: ...Tracks User Manual 3 Technical Data ...
Page 93: ...Tracks User Manual 5 Operation ...
Page 97: ...Tracks User Manual 9 Maintenance ...
Page 103: ...Tracks User Manual 15 Notes ...
Page 104: ...16 Tracks User Manual Date Notes NOTES ...
Page 105: ...17 Tracks User Manual Date Notes NOTES ...
Page 106: ...18 Tracks User Manual Date Notes NOTES ...
Page 107: ......